Installation Manual
H3C S3100 Series Ethernet Switches
Chapter 1 Product Introduction
1-9
Note:
z
With a PoE card inserted in one expansion slot, an S3100-16C-SI Ethernet switch
will be a powered device (PD). In this case, the other expansion slot becomes
unavailable.
z
For details about LEDs on the front panel, refer to section 1.4.1 “Front Panel LEDs
of the S3100-SI/S3100-TP-PWR-EI/S3100-C-EPON-EI Series”.
II. Rear panel
Figure 1-11 shows the rear panel of an S3100-16C-SI AC-powered Ethernet switch.
(1) AC power socket
(2) Grounding screw
Figure 1-11
Rear panel of an S3100-16C-SI AC-powered Ethernet switch
Figure 1-12 shows the rear panel of an S3100-16C-SI DC-powered Ethernet switch.
(1) DC input terminal block
(2) Grounding screw
Figure 1-12
Rear panel of an S3100-16C-SI DC-powered Ethernet switch
III. Power system
1)
S3100-16C-SI AC-powered Ethernet switches:
z
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
z
Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
2)
S3100-16C-SI DC-powered Ethernet switches:
z
Rated voltage range: –48 VDC to –60 VDC
z
Input voltage range: –36 VDC to –72 VDC
IV. Cooling system
The S3100-16C-SI cools off naturally.