Starting the Econox
To start the Econox, place the selector switch on “START”, it will start the feed pump.
Keep the selector on this position until the pump starts working. Once the pressure pump
works, let go of the selector and it will automatically go to the “ON” position. A delay of a
few seconds is expected before the recirculation pump starts.
Stopping the system
To stop the Econox, place the selector switch on “OFF” this will stop simultaneously stop
all the pumps. The Econox also has a few protective dispositions that will stop
simultaneously the system in case of problems. Related to the luminous indicator:
High temperature water
Low pressure at the entrance of the pressure pump
Motor error
General characteristics
Main module specification
Power supply required: 120/240 volts, 60 Hz, single-phased
Dimensions:
Height : 72" (183 cm)
Width :
27" (69 cm)
Depth :
30 " (76 cm)
Plumbing connection:
Maple sap inlet :
1 ½ " PVC slick
Permeate outlet :
quick adaptor 1" PVC type A
Concentrate outlet :
quick adaptor 1" PVC type D
Drain :
1 ½" PVC slick
Feeding pump:
Stainless steel pump, equipped with a motor 1 HP or 2 HP, 60 Hz, 3500
rpm, 230 volts single-phased.
Pressure pump:
With a motor of 5 HP or 7.5 HP, 60 Hz, 3500 rpm, 230 volts single-phased.
Recirculating pump:
With a motor of 1 HP, 60 Hz, 3500 rpm, 230V.
Содержание ECONOX
Страница 1: ...H2O Innovation 819 344 2288 usine h2oinnovation com ECONOX Separator for Maple Grove ...
Страница 8: ...8 Provision of the electrical components ...
Страница 11: ...11 ...
Страница 26: ...26 VI ANNEXES ...
Страница 29: ...29 Feed pump specification sheet 1HP ...
Страница 30: ...30 Feed pump specification sheet 2HP ...