13
W
ARNING
:
Frequently check prefilter F-I, most importantly before each concentration
cycle and during operation.
Change the filter cartridge when you note a difference of more than 20 psi of
pressure between the two pressure gauges.
Immediately (or at least inside the next 30 minutes) following a
concentration cycle, you must run a rinse cycle (see page 14) to eliminate
bacteria and sugar.
Flow calculation of the Econox
It is easy to calculate the Econox flow. Simply add the flow of concentrate to
the flow of permeate
Flow meters are in gallons per minute.
Readings are taken at the top of the float
Example
Readings are: 4 GPM of concentrate and 6 GPM of permeate
Total flow: 4 GPM + 6 GPM = 10 GPM