5
1. Do not install the product in the following places.
C. Caution for Installation
• Near fires
• Where there may be snow or rain
• Chemicals (volatile materials, organic solvents, etc.)
• Places where the temperature may fall below 0
o
C
2. Please use the following water quality range.
3. Do not connect hot water (above 38
o
C) to the product.
This may cause performance deterioration and failure.
4. Do not tilt more than 45
o
when transporting the product.
Tilting it excessively may cause performance deterioration.
5. Do not operate the appliance without leveling.
It may cause malfunction or failure.
6. Do not install on inclined or unstable places.
This may cause performance deterioration, falls, and injury.
7. When connecting the tubing hose, do not allow the tubing hose
to be
bent or pressed against heavy objects.
May cause malfunction.
8. When installing more than one product (water purifier, dishwasher,
etc.) and this product in one place, be sure to install raw water and
hoses separately for each product.
Every product has a different incoming water specifications.
• Water pressure: 1.4 ~ 7 kgf /
cm
2
(137 ~ 686 kPa, 1.37 ~ 6.86 bar)
• Water temperature: 4 ~ 38
o
C
• PH: 5.8 ~ 8.5
• Hardness: 300 ppm or less
• Turbidity: 0.5 NTU or less
• Water quality: Water quality that meets drinking standard
(Not available for uncertified drinking water quality standards and undetermined groundwater)
- Do not install in the low water pressure area below 1.4 kg /cm
2
- Please consult with us when using in other water quality.
- If you do not use the water quality as specified above, the product warranty
becomes null and void.