background image

www.h2flow.net  

  Tel: 888-635-0296 (Toll Free)  

OR

  (+1) 419-841-7774 (International)

13

E. Damping

Adverse effect of sudden changes of flow rate or laminar flow disturbances in measuring section of the instrument (e.g., due 

to fittings, bends or pumps) sensed by the instrument and causing sudden changes of displayed values or oscillations of 

current output can be eliminated by setting of instrument damping.

1.  Use cursor keys to select the option 

DAMPING

 from the main menu and confirm your selection with the 

EXE

 button. A 

submenu will be displayed.

2.  Select option 

TIME

 and confirm your selection by pressing the 

EXE

 button.

3.  Select 

TIME CONSTANT

 from the submenu and confirm it by pressing the 

EXE

 button. Generally, the longer the time 

constant is, the more stable the value is on the display and on the outputs; however,  this option is also slower to respond 

to flow changes, i.e., with time constant of 5 seconds, the instrument responds to an immediate drop of flow and displays 

zero flow rate only after 5 seconds.

4.  Select the option 

MODE

 and confirm by pressing the 

EXE

 button. Select 

LINEAR

 if damping is to be linear or 

AVERAGE

 

if it should be calculated from several saples depending on selected time constant. Confirm your selection by pressing 

the 

EXE

 button.

5.  In option 

ZONE

, select the command 

EDIT

 and press the 

EXE

 key to enable editing of bandwidth above and below stead 

flow mean value in which damping should occur. Use the cursor keys to set numeric value in l/s and confirm it by pressing 

the 

EXE

 button.

6.  Select the 

RETURN

 option to complete the setup.

The instrument will ask if you want to save new parameters by displaying the text 

SAVE SETUP?

. Select 

YES

 to confirm. The 

flow meter will save the new parameters and switch to the normal display mode. If 

NO

 is selected, parameters will not be 

saved.

The instrument will switch to display mode and work with the new parameters until it is switched off. When the instrument is 

switched on again, it will use the original/default parameters.

D. Display

Measuring units and decimal point position are set by default in the factory and correspond to the size of the flow meter.

If this default setting does not conform to your requirements, you can change it in the main menu using the 

DISPLAY

 option, 

and in the submenu using by selecting 

UNIT

 (units of immediate flow rate) and 

DECIMAL POINT

 (selection of places after the 

decimal point for flowed quantity).

Содержание FaraMag FM500

Страница 1: ... NOTE For the most up to date version of this manual please visit www h2flow net product literature English Rev 1 2 6 2020 www h2flow net Tel 888 635 0296 Toll Free OR 1 419 841 7774 International Operating Manual EN FM500 MODELS ...

Страница 2: ...10 B multi functional outputs 11 B 1 pulse setting 11 B 2 status report setting 12 C analog output 12 D display 13 E damping 13 F dead band setting 14 G datalogger 14 G 1 datalogger setting without time mask 15 G 2 datalogger setting with time mask 15 G 3 examples of time mask setting 16 G 4 datalogger sub menu 16 H function of the third electrode 17 I password setting 17 J GSM module activation 1...

Страница 3: ...r status outputs and the third one as an active current output The standard delivery also includes an internal data logger and RS232 communication port A GSM module for remote data reading via SMS text message can be ordered as an option Setting of flow meter parameters is performed using the keyboard and intuitive display menu or using service software via the RS232 communication port 3 2 flow ra...

Страница 4: ...ning 22 302 F 30 150 C for PTFE lining VOLTAGE 230VAC standard 12 24 VAC VDC optional INPUT POWER 10 VA max OUTPUTS 1 x programmable multi functional pulse status isoluated relay load 125 V 1A or 30V 2A 1 x programmalbe multi functional pulse status isolated transistor NPN load 30V 50mA max 1 x programmable active current 0 20mA 4 20mA load 500 Ω 1 x RS232 COMMUNICATION RS232 keyboard permanently ...

Страница 5: ...50 5 71 145 3 5 88 9 6 6 3 0 0 75 5 90 150 5 90 150 3 90 98 6 7 7 3 5 1 5 90 150 6 10 155 4 25 108 8 8 4 0 1 25 5 90 150 8 66 220 4 62 117 3 10 6 4 8 1 5 5 90 150 9 06 230 5 0 127 11 0 5 2 7 87 200 9 45 240 6 0 152 17 6 8 2 5 7 87 200 10 23 260 7 0 178 19 8 9 3 7 87 200 10 83 275 7 5 191 24 3 11 4 9 84 250 11 81 300 9 0 229 33 1 15 5 9 84 200 13 19 335 10 254 44 9 19 6 11 81 300 14 17 360 11 279 5...

Страница 6: ...d with the measured liquid and the measuring section cannot be influenced by any disturbing elements such as valves pumps bends or sharp deviations in the tubing section Please observe the following instructions when installing the flow meter into the tubing 1 If the system includes pumps never place the flow meter sensor into the pump intake A 2 Place the flow meter sensor into the lowest point o...

Страница 7: ...FLOW METER IS AN ELECTRONIC DEVICE THE FOLLOWING STEPS SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN TERMINAL BLOCKS Terminal Description FLOW C tube flooding indication electrode FLOW A measuring electrode FLOW B measuring electrode FLOW ground terminal of the sensor PWR D solenoid PWR E solenoid BIN1 programmable multi functional output BIN2 programmable multi functional output ANAL programmabl...

Страница 8: ...cted before the power supply is connected to the transducer If the power cable has already been connected to the transducer connecting and disconnecting of the link cable when the transducer is under voltage is prohibited 3 The induction flow meter is powered by mains voltage 230V 60Hz connected to the power supply terminal block labelled as L PE N or by low voltage 12 VDC or 24 VAC connected to t...

Страница 9: ...a date hour minute and total volumes in particular time In addition to this data the instrument will also display one of the following optional values Immediate flow rate Q Maximum flow rate reached during particular period MAX Minimum flow rate reached during particular period MIN Average flow rate reached during particular period AVR Average Briefly press the button to return the instrument to b...

Страница 10: ...Spanish German ANALOG OUTPUT Configuration of analog output PULSE OUTPUTS Configuration of multi functional pulse outputs COMPARATOR Selection of logical functions for multi functional pulse outputs FREQUENCY OUT Configuration of frequency output DAMPING Instrument damping COMMUNICATION Configuration of communication ports RS232 GSM modem DATALOGGER Configuration of internal data logger SIMULATION...

Страница 11: ...NG CYCLE OF 640 MS PULSE CAN BE ASSIGNED ONLY SUCH VOLUME AND WIDTH SO THAT THE NUMBER OF TRANSMITTED PULSES DURING TIME UNIT IS REAL INCORRECT SETTING IS INDICATED BY AN ERROR MESSAGE DISPLAY SHOWS THE CODE E5 1 Use the cursor keys to select the option PULSE OUTPUTS from the main menu and confirm your selection with the EXE key A sub menu will be displayed 2 Select PULSE WIDTH under options ms im...

Страница 12: ...e active current output on terminals ANAL The output can be configured for 4 20 mA or 0 20 mA 1 Use cursor keys to select the option ANALOG OUTPUT from the main menu and confirm your selection by pressing the EXE button A submenu will be displayed 2 Select the option Ia and confirm your selection by pressing the EXE button 3 In the submenu select the mode of current output 4 20 mA 0 20 mA or OFF i...

Страница 13: ...be linear or AVERAGE if it should be calculated from several saples depending on selected time constant Confirm your selection by pressing the EXE button 5 In option ZONE select the command EDIT and press the EXE key to enable editing of bandwidth above and below stead flow mean value in which damping should occur Use the cursor keys to set numeric value in l s and confirm it by pressing the EXE b...

Страница 14: ...s switched on again it will use the original default parameters G Datalogger The internal datalogger enables recording of measured values in chosen intervals either periodically or one at a time and their storing in the instrument s memory Stored values can be subsequently read on the display or on a PC via the RS232 communication link The datalogger records the following parameters by default tot...

Страница 15: ...he set up The instrument will ask if you want to save the new parameters by displaying the text SAVE SETUP Select YES to confirm and the flow meter will save the new parameters and switch to normal display mode If NO is selected parameters will not be saved The instrument will switch to display mode and work with the new parameters until it is switched off When the instrument is switched on again ...

Страница 16: ...etting xx xx xx xx 00 recording starts every rounded hour 15 xx xx 11 30 recording starts every 15th day in month at 11 30 15 11 xx 11 30 recording starts every 15th November at 11 30 15 11 19 11 30 recording starts only on 15 11 2019 at 11 30 x1 xx xx 11 30 recording starts each Monday at 11 30 x2 xx xx 11 30 recording starts each Tuesday at 11 30 x3 xx xx 11 30 recording starts each Wednesday at...

Страница 17: ...indicate that this function has been enabled 1 Select the MEASUREMENT option from the main menu and confirm your selection by pressing the EXE button A sub menu will be displayed 2 Select the ALARM command under the option EMPTY PIPE to activate the above described function c Function of the third electrode can be completely disabled 1 Select the MEASUREMENT option from the main menu and confirm y...

Страница 18: ...sing the EXE button A sub menu will be displayed 3 Select the GSM command and press the EXE key to display the next sub menu Select the INIT option and confirm your selection by pressing the EXE button The message GSM INIT OK will be shown on the instrument display 4 Select the RETURN option to complete the set up The instrument is ready for sending SMS messages Send SMS messages in format F3 spac...

Страница 19: ...www h2flow net Tel 888 635 0296 Toll Free OR 1 419 841 7774 International 19 11 notes PROBLEM SOLUTION Sample Solution 1 Solution 2 Sample Solution Sample Solution 1 2 3 4 5 6 ...

Страница 20: ...amage has been caused by the improper use of the product including but not limited to breakage or damage to the instrument sensors or cracking of the instrument display exposing the display to sunlight or corrosive chemicals the splicing or cutting of cables or wires unless explicitly instructed to do so during the installation process General misuse of the product Charges Under cover of this warr...

Отзывы: