17
16
| Features
Temperature Switch TS 1000
WarnIngS anD SaFeTy InSTrucTIonS
Please read this manual carefully.
It contains important information for the safe
operation and use of this device. The law requires that we give you important
information for your safety and that we point out how to avoid damage to
persons, the device and the connected devices. No liabilities will be taken
for damages or claims resulting out of not reading and/or not following the
user guide and/or any form of modification on or in the product. Under these
circumstances, no warranty services will be given. Liability will not be taken for
consequential damages. These instructions are part of the device and should
therefore be stored carefully. In order to avoid malfunction, damage and health
problems, please follow the safety instructions carefully:
– Repairs may only be carried out by an expert.
– Dispose of the packaging material and keep it out of reach of children. There
is a danger of suffocation
– Electrical devices do not belong in the hands of children. Store the device in
a safe place.
Danger!
The device may only be opened by a qualified electrician!
An open device has accessible live components. The mains plug must
be pulled before the device is opened.
The TemperaTure SWITch TSm 1000
is ideal for all
applications where a temperature controlled heating or cooling
mode is required. An external temperature sensor can detect
ranges from –99°C to +850°C. Examples of applications are
the control of central heating, air conditioning or even incubators.
The unit can also be used in the form of an independent monitor
as a frost guard, as a substitute for defective mechanical thermo-
stats or even as a digital thermometer.
TemperaTure SWITch
TS 1000
Art.-No. 1 11 44 70
gB
FeaTureS
– PT 1000 temperature sensor (not included)
– Switching Temperatures from –99 to +850°C
– Minimum / maximum display
– Freely adjustable hysteresis
– Serial interface (optional)
– Sensor monitoring for short-circuit and open-circuit
– Output switches off if sensor error occurs
– Easy to use: maintenance-free operation
– Adjustable for Heating and Cooling
– LED indicators for Relay ON/OFF, Sensor Fault, Heating and Cooling
– Programmed thresholds stored at power loss. New programming not required
TechnIcal DaTa
– Operating voltage: 10–15VDC
– Output voltage: 230 V A/C Max 5 A or 30VDC/5A
– Power consumption: approx. 60mA
– Switching capacity: max. 1000 W
– Sensor input: Pt 1000 (2-Wire)
– Measuring range: -99 To +850°C
– Accuracy: ≤0.5% Fs ± 0.1°C
– Resolution: 0.1°C
– IP-Protection: IP 20
– Dimensions (front): 97 x 43 mm
noTIce!
Read instruction
manual carefully
before operating
the device!