background image

                  

433MHZ REMOTE THERMO

INTRODUCTION:

Congratulations  on  purchasing  this  innovative  433MHZ  Remote  Thermo  which  displays  the  time  with  up  to  the 

minute indoor and up to five uotdoor temperature readings. To enjoy the full benefits of this innovative product, 

please read this operating manual.

TEMPERATURE TRANSMITTER:

FEATURES:

  -  LCD clock in 24 hour time display (hour, minutes, seconds)

  -  DCF-77 Radio Controlled time with manual setting

  -  Indoor and outdoor temperature reading in degree Celsius (

C)

  -  Can receive up to five Outdoor transmitters

  -  Indoor and outdoor temperature with Minimum and Maximum records and time received for outdoor only

  -  Table standing or wall mountable (detachable table stand)

SETTING UP:

Please  follow  these  steps  to  ensure  that  your  new  Remote  Thermo  works  correctly  with  the  temperature 

transmitter(s):

  1.  Flip open the battery cover at the back of the Remote Thermo as indicated above.

  2.  Checking the correct polarization, insert 2 x AA, IEC LR6, 1.5 V batteries into the battery compartment and 

replace the cover (all the segments of the LCD screen will light up momentarily.

  3.  Remove the battery cover at the front side.

  4.  Checking the correct polarization, insert 2 x AAA, IEC LR3, 1.5 V batteries into the battery compartment and 

replace the cover.

  5.  If you have purchased additional outdoor transmitter(s) wait until the outdoor temperature has been received 

from the one transmitter before activating the next transmitter by repeating steps 3 and 4.

  6.  However, ensure that you leave 10 seconds in between the reception of the last transmitter and the set-up of 

the following transmitter. The remote Thermo will number the transmitters in the order of set-up, i.e. the first 

transmitter will have the temperature displayed with the number 1 against it and so on.

  7.  When the outdoor temperature(s) is received the Remote Thermo and transmitter(s) should be positioned in the 

desired places (see Positioning & securing below)

NOTE:

Should the total time of inserting the batteries into the transmitters take longer than 2-1/2 minutes from the time

of  inserting  the  batteries  into  the  Remote  Thermo  then  temperature  reception  problems  may  occur.

If the temperature is not by received, then see Checking for 433 MHz reception, before resetting the units (see 

Resetting the Remote Termo below).

In the event of changing batteries in any of the units, all units need to be reset by following the setting up procedures. 

This is because a random security code is assigned by the transmitter at start-up and this code must be received

and stored by the Remote Thermo in the first 2-1/2 minutes of power being supplied to it.

LCD SCREEN

The Remote Thermo’s LCD is comprised

of three lines and once the batteries

are inserted, all the segments

will light up momentarilly before displaying:

  1.  Time „-:--“

  2.  Indoor temperature

    in degree Celsius (

o

C)

  3.  Outdoor temperature

    in degree Celsius (

o

C)

GB

WS7206navod - 6

CHECKING FOR DFC-77 RECEPTION:

The Remote Thermo will automatically start scanning for the DFC-77 frequency signal after the battery is inserted. 

In normal surroundings (for example away from interfering sources such as TV sets), it takes between 3-5 minutes

to receive the signal. If after 10 minutes after having inserted the batteries into the alarm clock and the DCF-77 

signal is not received, then check the following list before manually setting the time (see Manual time setting):

  1.  The distance of the Remote Thermo should be at least 1.5-2.0 meters away from interfering sources such

as computer monitors or TV sets.

  2.  Avoid  placing  the  alarm  clock  onto  or  in  the  immediate  proximity  of  metal,  doors,  windows  frames

or structures.

  3.  Within  thick  concrete  rooms  such  as  basements  and  tower  blocks,  the  DCF-77  signal is  naturally weaker.

In extreme cases, place the alarm clock closer to a window and/or point its front or rear towards the general 

direction  of  the  Frankfurt/Main  transmitter  (avoid  positioning  within  close  proximity  of  metal  frames

or structures).

Note:

Users may be located in areas where atmospheric disturbances are the direct cause for not receiving the DCF-77 

frequency  signal.  During  nighttime,  atmospheric  disturbances  are  usually  less  severe  and  reception  is  posible

in most cases. With a single daily reception, it is adequate for the alarm clock to keeptime deviation to below

0.5 seconds in a period of 24 hours.
When  the  clock  is  trying  to  receive  the  DCF  signal,  the  reception  icon  will  flash  on  the  LCD.  Once  the  signal

is  „locked“,  the  DCF-77  tower  icon  will  stay  fixed  on  LCD  and  the  received  time  will  automatically  correct

the manually set time. As well as the time, the date will also be received by the Remote and will be displayed 

accordingly in the calendar section of the LCD.

TIME SETTING:

After the batteries are inserted, set the time display as follow:

  1.  Press and hold the „SET“ key about 3 seconds to enter the set mode. The Hour digit in the time section starts 

flashing

  2.  Using the „IN“key, enter the hours of the current time and then followed by pressing the „OUT“ key to enter the 

minutes of the current time.

  3.  Press the „SET“ key to exit the setting mode. Your Remote Thermo is now fully operational.

USING THE REMOTE THERMO:
INDOOR TEMPERATURE:

The indoor temperature is displayed on the second line of the LCD˝under the time. The Remote Thermo’s built in 

sensor automatically measures the temperature once the batteries are inserted.

MINIMUM AND MAXIMUM INDOOR TEMPERATURE RECORDINGS:

By pressing „IN“ key the current indoor temperature will alternate between the minimum, maximum and current 

temperature recordings. Once a new indoor temperature high or low is reached, it will automatically set into the 

Remote Thermo’s memory.

OUTDOOR TEMPERATURE READING:

The outdoor temperature reading is on the bottom line of the LCD under the indoor temperature. The Remote Thermo 

receives the outdoor temperature via 433 mhz frequency when the batteries are inserted into the transmitter within 

the 2-1/2 minutes of the setting up time (See Setting up above).

Note:

Should the outdoor temperature not be received within 2-1/2 minutes after inserting the batteries into a transmitter, 

then see „Checking 433 MHz reception“ below.

MINIMUM AND MAXIMUM OUTDOOR TEMPERATURE READING:

By  pressing  the  „OUT“  key  the  current  indoor  and  outdoor  temperature  will  alternate  between  the  minimum, 

maximum and current temperature recordings. The time when the minimum and maximum outdoor temperature 

records were received will be also shown on the LCD blinking (recorded time is for outdoor temperature only). Once

a new outdoor temperature high or is low reached, it will automatically be set into the Remote Thermo’s memory.

RESETING THE MINIMUM AND MAXIMUM TEMPERATURE RECORDING:

By pressing and holding down the „IN“ or „OUT“ key about 3 seconds then pressing the „RESET“ key, the indoor or 

outdoor minimum and maximum temperature recordings will be reset to the current indoor or outdoor temperatures. 

Only the outdoor temperature display on the LCD will be reset. To reset another outdoor temperature, move to the 

desired transmitter number by pressing the „RESET“ key.

OUTDOOR TEMPERATURE 1, 2, 3, 4 AND 5

If the more than transmitter is being used, to alternate between the temperature readings of transmitter 1, 2, 3, 

4, and 5 simply press the „RESET“ key. If the reading is from transmitter 1, then the identification numbers 1 will 

be displayed in the outdoor tempereture section of the LCD. The same will apply to the next transmitter and so on. 

However, if only one transmitter is used, no identification number will be displayed on the LCD.

CHECKING FOR 433 MHz RECEPTION:

In normal surroundings (for example away from interfering sources such as TV sets), the outdoor temperature can 

usually be easily received within 2-1/2 minutes. If the outdoor temperature is not displayed on the LCD after 2-1/2 

minutes, then check the following:

  1.  The distance of the units should be at least 1.5 - 2.0 meters away from interfering sources such as computer 

monitors or TV sets.

  2.  Avoid placing the units onto or in the immediate proximity of metal doors, window frames or structures.

  3.  Using other electrical product such as headphones and speakers that operate on the same signal (433 MHz) 

can prevent the transmission pick up.

  4.  Neighbours using electrical products operating on the 433 MHz signal can also cause interference. In most 

severe cases, the reception is only possible once all other electrical products using the 433 MHz are switched off.

  5.  Within thick concrete rooms such as basements and tower blocks, the 433 MHz signal can be weakened (avoid 

placing near metal frames and structures).

  6.  Transmission can be affected by exposure to extreme temperature conditions. For example, if the weather 

has been extremely could (under -25

o

C) for an extended period of time then the transmission signal may be 

weakened. (Please bears this in mind when positionig the transmitter).

Note:

Should after checking the above list and the outdoor temperature is still not received, then reset the units (see 

Resseting the Remote Thermo below).

RESETING THE REMOTE THERMO:

  1.  Remote the batteries from the Remote Thermo and the transmitter(s)

  2.  Wait at least 30 seconds and repeat the procedures specified in Setting up above.

Note:

Remember when resetting, all units have to be reset and to always insert the batteries into the Remote Thermo first 

and then followed by the transmitter(s).

POSITIONING REMOTE THERMO:

The  Remote  Thermo  comes  complete  with  a  detachable  stand  that  gives  the  option  of  table  standing  or  wall 

mounting.

To wall mount:

  1.  Fix a screw into the desired wall, leaving the head extended out the by about 5mm

  2.  Using the Remote Thermo’s hanging hole, carefully hang it onto the screw

Note: Always ensures that the unit locks onto the screw head before releasing.

OUTDOOR TRANSMITTER:

The  Outdoor  Transmitteris  supplied  with  a  holder  that  may  be  attached  to  a  wall  with  the  three  screws  or 

double-sided tape supplied.

To attach to the wall using screws, please follow the steps below:

  1.  Mark the awall using a pen through the holes in the holder to obtain the exact drilling position.

  2.  Drill holes in the wall at the points marked.

  3.  Screw holder onto wall.

The Outdoor Transmitter simply clicks in or out of the holder. When inserting or removing the Outdoor Transmitter to 

or from the wall holder please hold both units securely to avoid tearing the holder from the wall.
There is also double sided tape included with the wall holder. On smooth surfaces this can be used instead of drilling 

holes. The mounting surface can, however, affect the transmission range. If for example the units is attached to

a piece of metal, it may then either reduce or increase the transmitting range. For this reason, we recommend not 

placing the unit on any metal surfaces or in any position where a large metal or highly polished surface is in the 

inmediate  proximity  (garage  doors,  double-glazing,  ets.).  Before  securing  in  place,  please  ensure  that  Remote 

Thermo can receive the 433 MHz signal from Outdoor Transmitter at the positions that you wish to situate them.

BATTERIES REPLACEMENT & MAINTENANCE:

For best performance, batteries to all units should be replaced at least once a year to maintain optimum running 

accuracy. Ensure that the batteries used are new of the correct size.

Please help in the preservation of the environment and return used batteries to an authorized depot.
CARE AND MAINTENANCE:

  -  Avoid placing the units in areas prone to vibration and shock as these may cause damage.

  -  Avoid areas where the units can be exposed to sudden changes in themperature , i.e. direct sunlight, extreme 

cold and wet/moist conditions as these will lead to rapid changes in temperature which reduces the accuracy 

of readings.

  -  When cleaning the LCD and casing, use a soft damp cloth only. Do not use solvent or scouring agents.

  -  Do not submerge the units into water.

  -  Immediately remove all low powered batteries to avoid leakage and damage. Replace only with new batteries 

of the recommended size.

  -  Do not make any repairs to the units. Please return them to the original point of purchase for repair by a 

qualified engineer. Opening and tampering with the units may invalidate its guarantee.

SPECIFICATIONS:

Temperature measuring range:

    Indoor: 

 

5

o

C to +65

o

C with 0.1

o

C resolution  (--:- displayed if outside this range)

    Outdoor:   

-29

o

C to +69

o

C with 0.1

o

C resolution  (--:- displayed if outside this range)

Temperature checking intervals

    Indoor temperature: 

every 10 seconds

Remote Thermo Outdoor

    Temperature reception: 

twice in 10 minutes

Transmitting frequency: 

433.92 MHz

Temperature transmitting: 

range up to 25 meters  (open space and free from interference)

Power source:

    Remote Thermo 

2 x AA, IEC LR6, 1.5 V batteries

    Transmitter 

2 x AAA, IEC LR3, 1.5 V batteries

Battery life for both units: 

Approximately 12 months (alkaline batteries recommended)

Dimensions (L xW x H): 

Remote Thermo  73.5 x 27 x 158 mm (stand included)

     

 

Transmitter 

59 x 21 x 65 mm (wall bracket excluded)

LIABILITY DISCLAMER:

  -  The  manufactured  and  supplier  cannot  accept  any  responsibility  for  any  incorrect  readings  and  any 

consequences that occur should an inaccurate reading take place.

  -  This product is designed for use in the home only as indication of the temperature.

  -  This product is not to be used for medical purposes or for public information.

  -  The specifications of this product may change without prior notice.

  -  This product is not a toy. Keep out of the reach of children.

  -  No part of this manual may be reproduced without written authorization of the manufacturer.

R&TTE Directive 1999/5/EC

Summary of the Declaration of Conformity: We hereby declare that this wireless transmission device does comply 

with the essential requirements of R&TTE Directive 1999/5/EC.

Battery compartment

Battery cover

Holder

Function Keys

Detachable stand

Battery cover

Hanging hole

Outdoor

transmission signal

Outdoor Temperature

in 

o

Transmitter

identification number

Time

Indoor

Temperature in 

o

Отзывы: