14
NEOSTART 320 / 420 / 620
EN
Translation of the original instructions
CHARGE (12-24V)
BOOST 1 (12-24V)
Neostart 320
40 - 160 Ah (11A)
90 - 400 Ah (27A)
For the NEOSTART 420 and 620 :
- Set the switch to CHARGE 1 or CHARGE 2 with regards to the battery capacity.
CHARGE 1 (12-24V)
CHARGE 2 (12-24V)
Neostart 420
25 - 90 Ah (6A)
90 - 300 Ah (20A)
Neostart 620
45 - 140 Ah (10A)
140 - 450 Ah (30A)
After usage, follow the recommended disconnection procedure.
Charging several batteries simultaneously.
It is possible to charge several batteries simultaneously by connecting them in parallel. The positive terminals connected
to the red clamp and the negative terminals connected to the black clamp. These batteries or battery groups must be
of the same voltage, 12V or 24V.
Charging batteries in series is not recommended.
USE IN STARTER MODE
Preliminary precautions
• Do not disconnect the battery fom the vehicle. Connecting the battery can lead to the vehicle’s memory loss and a
potential impossibility to restart it.
Start
Once the charger is connected to the vehicle battery while following the instructions (see connections and disconnections),
it may be necessary to perform a pre charge in order to start the vehicle.
To perform a pre charge, set the switch to «BOOST 2» for the NEOSTART 320 and «BOOST» for the NEOSTART 420
and 620.
NEOSTART
320
:
Instantaneous
5 min pre charge
Neostart
320
12 V
35 - 60 Ah
60 - 120 Ah
24 V
35 - 45 Ah
45 - 90 Ah
NEOSTART 420 and 620 :
Instantaneously
5 min pre charge
Neostart 420
35 - 80 Ah
80 - 160 Ah
Neostart 620
45 - 100 Ah
100 - 200 Ah
To start the vehicle, set the switch to «START». Reach the vehicle controls. By turning the key, the start mode activates.
This mode must be stopped once the vehicle is started. It is recommended to do this with 2 people so that the person
close to the NEOSTART can switch to START at the exact moment and stop the device once the vehicle has startted.
If your engine does not start, wait 2 minutes between each start attempt. The attempt must last 3 seconds at most.
Nb : If the vehicle does not start, it may be a problem other than a faulty battery e.g. alternator, glowplug…
After the use, follow the disconnection procedure.
PROTECTIONS
These clamps have been designed for maximum protection :
• The charging clamps are fully insulated.
• A fuse guarantees protection against polarity inversion and short circuits.
- Neostart 420 and 620 : ref. 054547, calibre 200 A (type SIBA V-Fuse / open type)
- Neostart 320 : ref. 054639, calibre 150 A (type Littlefuse BF1 / 32 V)
Replacing it requires manual intervention..
• A breaker, on the front panel, guarantees protection against tranformer overloads and start attempts in charge mode.
If the breaker trips, it needs to be manually activated.
• The thermal protection is monitored by a thermostat (cooling for approximately 1/4h). The green indicator switches
off in the even of overheating.
130.com.ua