60
Operating manual
ARCPULL 350
Translation of the original
instructions
8.4.4.2. Information
Info machine
Soft gene V3.0
Hard gene V1.0
Pistolet 200-350
Soft pistolet V3.0
Hard pistolet V7.0
panel The information panel gives the software and hardware version numbers of the generator and, if the gun is
connected, its type (200-350, 700).
9. ERROR MESSAGE, ANOMALIES, CAUSES, REMEDIES
This equipment has a failure control system. In the event of a failure, error messages may be displayed.
Error message
Meaning
Causes
Remedies
DEFAUT THERMIQUE
Generator thermal pro-
tection.
Duty cycle exceeded.
Wait for the message to go out to
resume welding.
DEFAUT SECTEUR
Mains voltage fault.
Mains voltage out of tole
-
rance or missing a phase.
Have your electrical installa-
tion checked by an authorized
person. Reminder the station is
designed to operate on a single-
phase 208-240 Vac 50/60 Hz
network
TOUCHE APPUYEE
Keyboard fault.
A key on the keyboard is
pressed when the product
starts up.
Have the keyboard checked by
qualified personnel.