8.4.4. SETUP MENU
Configuration
> Pregaz > 400ms
Postgaz 400ms
Langue FR
Reset machine
Info
Press the G and G- keys to move the left cursor (Pre-gas, Post-gas, Language, Machine reset, Info.).
When the Pre-gas, Post-gas or Language items are highlighted, press the D and D- keys to modify their value.
Test
Setting range
Remark
Pre-gas
NoGas then from 0.2 s to 3 s
To weld under gas protection, it is advisable to have a pre-gas of at
least 0.4 s.
Post-gas
NoGas or from 0.2 s to 3 s
When welding is done under gas protection, it is recommended to
have a post-gas of at least 0.4 s.
Tongue
FR, GB, DE, NL, ES, IT, UK
Press the back button
to return to the Main Menu.
8.4.4.1. ResetMachine
When "Reset machine" is selected from the Configuration menu, pressing
returns the set to the machine reset
sub-menu.
Reset machine
:3sec
pour valider
To push on
for 3 s to validate the product reset.
Press back
to return to the Configuration menu and cancel the product reset.
A reset of the ArcPull 350
will clear all weld configurations from the Program menu, revert the product to