23
GYSPOT ARCPULL 200
EN
Placing a dowel pin holder (059634 - 059641)
• Insert the dowel pin holder in its support.
Dowel pin holder
Dowel pin holder support
• Put the protection nozzle on the dowel pin support and tighten slightly
• Reposition the electrode holder in the canon of the gun
Protective nozzle
• Put the protection pad at the end of the earth rods
• Tighten the two holding screws for the pad and make sure there is a
slight contact with the earth rods to guarantee electrical contact.
Pad
holding
screw
Pad
ERROR MESSAGE, ANOMALIES, CAUSES, SOLUTIONS
This equipment has a failure control system. In case of failure, error messages may be displayed.
Error code
Meaning
Causes
Solutions
OVERHEATING DEFECT
OVERVOLTAGE DEFECT
COM. DEFECT
Info
Soft gene V0.0
Hard gene V0.0
Soft gun V0.0
Hard gun V0.0
PRESSED KEY
zone de
message
Product reset
:3 sec
to reset
Configuration
> Pregas > 100ms
Postgas 500ms
Language EN
Product reset
Info
Synergic Settings
> Material > Fe
Gas ON
Electrode Ring
THK. elec. 1.5 mm
Main Menu
> Settings
Manual Mode
Configuration
t
ms
I
A
100
200
message
area
Manual Settings
Start-up > Q = 0
OVERHEATING DEFECT
MOTOR DEFECT
Ring 1.5mm
Fe Gas
+1
2.0
message
area
Generator thermal
protection
Maximum duty cycle
reached.
Wait for the indicator to turn off before resu-
ming welding operations.
OVERHEATING DEFECT
OVERVOLTAGE DEFECT
COM. DEFECT
Info
Soft gene V0.0
Hard gene V0.0
Soft gun V0.0
Hard gun V0.0
PRESSED KEY
zone de
message
Product reset
:3 sec
to reset
Configuration
> Pregas > 100ms
Postgas 500ms
Language EN
Product reset
Info
Synergic Settings
> Material > Fe
Gas ON
Electrode Ring
THK. elec. 1.5 mm
Main Menu
> Settings
Manual Mode
Configuration
t
ms
I
A
100
200
message
area
Manual Settings
Start-up > Q = 0
OVERHEATING DEFECT
MOTOR DEFECT
Ring 1.5mm
Fe Gas
+1
2.0
message
area
Mains voltage
default.
Mains power is out of
range or one phase is
missing.
Have your electrical installation checked by
a qualified person. The voltage between
phase and neutral must be between 100V
and 127Vac on a 110V supply network or
between 200V and 265Vac on a 230Vac
supply network.
OVERHEATING DEFECT
OVERVOLTAGE DEFECT
COM. DEFECT
Info
Soft gene V0.0
Hard gene V0.0
Soft gun V0.0
Hard gun V0.0
PRESSED KEY
zone de
message
Product reset
:3 sec
to reset
Configuration
> Pregas > 100ms
Postgas 500ms
Language EN
Product reset
Info
Synergic Settings
> Material > Fe
Gas ON
Electrode Ring
THK. elec. 1.5 mm
Main Menu
> Settings
Manual Mode
Configuration
t
ms
I
A
100
200
message
area
Manual Settings
Start-up > Q = 0
OVERHEATING DEFECT
MOTOR DEFECT
Ring 1.5mm
Fe Gas
+1
2.0
message
area
Keypad fault
A key on the keypad is
pushed when the machine
is switched on.
Ask a qualified person to check the keypad.
OVERHEATING DEFECT
OVERVOLTAGE DEFECT
COM. DEFECT
Info
Soft gene V0.0
Hard gene V0.0
Soft gun V0.0
Hard gun V0.0
PRESSED KEY
zone de
message
Product reset
:3 sec
to reset
Configuration
> Pregas > 100ms
Postgas 500ms
Language EN
Product reset
Info
Synergic Settings
> Material > Fe
Gas ON
Electrode Ring
THK. elec. 1.5 mm
Main Menu
> Settings
Manual Mode
Configuration
t
ms
I
A
100
200
message
area
Manual Settings
Start-up > Q = 0
OVERHEATING DEFECT
MOTOR DEFECT
Ring 1.5mm
Fe Gas
+1
2.0
message
area
Communication
fault with the gun
Communication between
the gun and the generator
is not working
Reconnect the gun and switch the machine
back on. If the fault remains, ask a qualified
person to check the product.
OVERHEATING DEFECT
OVERVOLTAGE DEFECT
COM. DEFECT
Info
Soft gene V0.0
Hard gene V0.0
Soft gun V0.0
Hard gun V0.0
PRESSED KEY
zone de
message
Product reset
:3 sec
to reset
Configuration
> Pregas > 100ms
Postgas 500ms
Language EN
Product reset
Info
Synergic Settings
> Material > Fe
Gas ON
Electrode Ring
THK. elec. 1.5 mm
Main Menu
> Settings
Manual Mode
Configuration
t
ms
I
A
100
200
message
area
Manual Settings
Start-up > Q = 0
OVERHEATING DEFECT
MOTOR DEFECT
Ring 1.5mm
Fe Gas
+1
2.0
message
area
Gun thermal pro-
tection
Maximum duty cycle
reached.
Wait for the indicator to turn off before resu-
ming welding operations.
OVERHEATING DEFECT
OVERVOLTAGE DEFECT
COM. DEFECT
Info
Soft gene V0.0
Hard gene V0.0
Soft gun V0.0
Hard gun V0.0
PRESSED KEY
zone de
message
Product reset
:3 sec
to reset
Configuration
> Pregas > 100ms
Postgas 500ms
Language EN
Product reset
Info
Synergic Settings
> Material > Fe
Gas ON
Electrode Ring
THK. elec. 1.5 mm
Main Menu
> Settings
Manual Mode
Configuration
t
ms
I
A
100
200
message
area
Manual Settings
Start-up > Q = 0
OVERHEATING DEFECT
MOTOR DEFECT
Ring 1.5mm
Fe Gas
+1
2.0
message
area
Gun motor fault
Gun mechanism is blocked Reconnect the gun and switch the machine
back on. If the fault remains, ask a qualified
person to check the product.
All operations requiring the removal of the machine’s cover and checking the electrical systems must be done by a
qualified technician.
Содержание GYSPOT ARCPULL 200
Страница 47: ...47 GYSPOT ARCPULL 200 RU 10 40 C 14 104 F 20 55 C 4 131 F 50 40 C 104 F 90 20 C 68 F 1000 3280 5 9...
Страница 48: ...48 GYSPOT ARCPULL 200 RU 10 11 2...
Страница 49: ...49 GYSPOT ARCPULL 200 RU A CEI 61000 3 12 EN 61000 3 11 Zmax 0 45 IEC 61000 3 11 C EMF EMF b c d e f...
Страница 50: ...50 GYSPOT ARCPULL 200 RU g h 10 CISPR 11 2009 a b c d e f 10 IP21 12 5...
Страница 56: ...56 GYSPOT ARCPULL 200 RU 12 cm 049000 048157 048164 3 3 059634 059641...
Страница 87: ...87...
Страница 88: ...88 GYS SAS 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex France...