17

GYSFLASH 50-12 HF

EN

4

Screen flashing :

 

« >50A » 

 

+ alarm beep

Consumption exceeds the output of the charger

Turn off electrical  consumers to reduce power demand

5

The GYSFLASH delivers a high cur-

rent (greater than 10A) before the 

diagnostic tool has been activated.

Several consumers are active on the vehicle

GYSFLASH works to specification. Turn off consumers to check the battery is not 

too discharged (see cause n°2).

Battery discharged

Battery deeply discharged, the GYSFLASH delivers current to charge it. Wait 

until the output current is below 10A to start the diagnostic.

6

Displays for 1s : 

« no battery »

 

+ alarm beep

Showroom mode is working on 

« no battery »

Showroom without battery : GYSFLASH operating normally. 

To deactivate the "no battery" function, press the "START/STOP" key, and then 

press the "START/STOP" key again to start the Showroom mode with battery.

7

The device is locked in Showroom 

mode

Lock Showroom active

Normal operation of GYSFLASH. 

Refer to configuration menu to deactivate this function.

8

Screen displays : 

« #error temp(°C) »

 

+ alarm beep

Faulty fan

Contact your distributor.

Extended exposure to sunlight

Do not leave the device exposed to sunlight. 

Leave the device ON until the fault disappears. (The alarm beep can be stoppe-

dPossibility to stop the alarm beep by pressing the START/STOP key).

9

Screen displays : 

« #error IHM 

» 

+ alarm beep

Electronic fault

Contact your distributor.

10

Screen displays : 

« #error fuse 

» 

+ alarm beep

Mishandling

Internal fuse must be changed by a qualified person 

(ref. 054653 : 80A).

11

The device doesn't display anything

Input fuse HS

Input fuse must be changed by a qualified person 

(fusible temporisé 10A 5x20).

Faulty electrical network

Check the voltage of the electrical network is between 180V and 260V.

SAFETY

▪ Explosive gas, avoid flame and sparks. During the charge, the battery must be placed in a well ventilated area.

▪ Acid projection hazard.

▪ Protect against rain and moisture.

▪ The charger must be connected to an EARTHED power supply.

▪ If the electricity supply cable is damaged, or if the internal fuse has blown (ref 054653), it must be replaced by the manufacturer,

its after sales service, or a qualified person.

▪ Do not use to charge small batteries (i.e those with a capacity less than the minimum stated on the Gysflash), or non rechar

-

geable batteries.

▪ Always ensure the Red clamp is connected to the "+" battery terminal first.

▪ If it is necessary to connect the black clamp to the vehicle chassis, make sure it is a safe distance from the battery and the fuel/

exhaust pipe.

▪ After charging, disconnect the charger from the outlet, then disconnect the clamp from the earth and the battery in the indicated

order.

▪ The charger must be positioned so that the socket is always accessible.

▪ This charger is not a toy.

▪ This product should be disposed of at an appropriate recycling facility - do not dispose of in domestic waste.

▪ Do not short-circuit the clamps during use.

Содержание GYSFLASH 50-12 HF

Страница 1: ...73502 V5 15 03 2016 EN 10 17 50 52 GYSFLASH 50 12 HF...

Страница 2: ...automatic restart feature enabling in Charge Showroom and Power Supply modes to automatically restart the device in case of power cut The function Lock Showroom if activated restricts the device to S...

Страница 3: ...charging on vehicle it is recommended to reduce the electrical consumption of the vehicle to a minimum switch off the lights close the doors in order to do not disturb the charging process DIAG MODE...

Страница 4: ...until the current falls below 10A before using any electical functions of the car CHANGE BATTERY MODE OPTIONAL The GYSFLASH will maintain a stabilised power supply to the vehicle during battery replac...

Страница 5: ...se in the sub menu press the Select key SELECT languages restart lock showroom cable check ADVANCED MENU Reset Memory Sub menu Languages This menu enables to select the language use the arrows to chan...

Страница 6: ...oblem occurred during the calibration In this case the calibration is reset to the factory setting Check that the cables are in good condition and properly put in short circuit and repeat the procedur...

Страница 7: ...time for shorted cells recovery adjustable from 1h to 12h Step 2 Trefresh Time for the refreshing phase adjustable from 1h to 12h If the value OFF is selected the refresh function is not activated St...

Страница 8: ...he MODE key to exit the Configuration menu MODE PROTECTIONS This device is protected against short circuits and polarity inversions It has an anti spark feature which prevents sparks whilst connecting...

Страница 9: ...lectronic fault Contact your distributor 10 Screen displays error fuse alarm beep Mishandling Internal fuse must be changed by a qualified person ref 054653 80A 11 The device doesn t display anything...

Страница 10: ...u 15 12 2004 03 05 1989 Dieses Ger t stimmt daher mit den erweiterten Normen berein EN 60335 2 29 EN 55014 1 EN 55014 2 EN61000 3 2 EN61000 3 3 EN62233 CE GS Kennzeichnung 2016 ATTESTACION DE CONFORMI...

Страница 11: ...r manual Achtung Lesen Sie die Betriebsanleitung Cuidado Leer el manual de instrucci n antes del uso Let op Lees aandachtig de handleiding voor gebruik T 10A FUSE 80A Assurer une a ration suffisante p...

Страница 12: ...a Nominale laad capaciteit 10 600 Ah Nombre de cellules Number of cells Anzahl der Zellen Cantidad de c lulas Aantal cellen 6 12V Consommation Batteries au repos Back Current Drain R ckstrom Consumo b...

Отзывы: