GYS GYSFLASH 50-12 HF Скачать руководство пользователя страница 3

11

GYSFLASH 50-12 HF

EN

CHARGE MODE CONFIGURATION DEPENDING 

ON THE BATTERY TYPE

Easy

Liquid

Gel/AGM

Expert

10Ah

11Ah

...

600Ah

CHARGE

12V

Gel/AGM

80Ah

12V

80Ah

12V

80Ah

CHARGE

Gel/AGM

CHARGE

Gel/AGM

Charging curves available if activated in 

«Advanced Menu».

Only for liquid, gel/AGM and expert  

charging curves.

Start up :

• Connect the clamps : red to the (+) and black 

to the (-) of the battery.

• Push the START/STOP key to start the charge.

• During the charge, the product alternates 

between displaying the progressing percentage 

of the charge, voltage, current, injected ampere 

hours and elapsed time.

• Push the START/STOP key again to stop the 

charge.

CHARGE MODE START UP 

10%

12V

80Ah

CHARGE

CHARGE

Gel/AGM

U=12.5V

Q=2.5Ah

I=10A

00h22

NB: When the charge ends (100%), if the battery remains connected the charger maintains the charge level of the battery by 

applying a floating voltage.

Precaution: 

Check the electrolyte level and fill if necessary before charging.

When charging on vehicle, it is recommended to reduce the electrical consumption of the vehicle to a minimum (switch off the lights,  

close the doors...) in order to do not disturb the charging process.

DIAG+ MODE

On a stationary vehicle the GYSFLASH supplies up to 50A to test high-energy consumers: engine fan, window regulator, electronic 

suspension, etc... By supplying a steady voltage:

- 12V to 14.8V

Voltage adjustment 

It is possible to adjust the voltage in steps of 0.1V according to manufacturer’s specifications.

DIAG + MODE CONFIGURATION

12.0V

12.1V

...

14.8V

DIAG+

U=13.5V

12V

DIAG+

U=13.2V

12V

Start up :

• Connect the clamps : red to the (+) and black to the 

(-) of the battery.

• Push the START/STOP key to start the mode.

• During use the current consumed and the instanta-

neous voltage are displayed.

DIAG+ MODE START UP

I=12A

U=13.5V

DIAG+

U=13.5V

12V

DIAG+

12V

 

Precaution :

 Before using the Diag+ Mode. If the screen displays a current greater than 10A, it indicates the battery is discharged. 

The device will start charging automatically. Check all electrical consumers are switched off on the vehicle. Wait until the current falls 

below 10A and then re-launch the diagnostic.

Содержание GYSFLASH 50-12 HF

Страница 1: ...73502 V5 15 03 2016 EN 10 17 50 52 GYSFLASH 50 12 HF...

Страница 2: ...automatic restart feature enabling in Charge Showroom and Power Supply modes to automatically restart the device in case of power cut The function Lock Showroom if activated restricts the device to S...

Страница 3: ...charging on vehicle it is recommended to reduce the electrical consumption of the vehicle to a minimum switch off the lights close the doors in order to do not disturb the charging process DIAG MODE...

Страница 4: ...until the current falls below 10A before using any electical functions of the car CHANGE BATTERY MODE OPTIONAL The GYSFLASH will maintain a stabilised power supply to the vehicle during battery replac...

Страница 5: ...se in the sub menu press the Select key SELECT languages restart lock showroom cable check ADVANCED MENU Reset Memory Sub menu Languages This menu enables to select the language use the arrows to chan...

Страница 6: ...oblem occurred during the calibration In this case the calibration is reset to the factory setting Check that the cables are in good condition and properly put in short circuit and repeat the procedur...

Страница 7: ...time for shorted cells recovery adjustable from 1h to 12h Step 2 Trefresh Time for the refreshing phase adjustable from 1h to 12h If the value OFF is selected the refresh function is not activated St...

Страница 8: ...he MODE key to exit the Configuration menu MODE PROTECTIONS This device is protected against short circuits and polarity inversions It has an anti spark feature which prevents sparks whilst connecting...

Страница 9: ...lectronic fault Contact your distributor 10 Screen displays error fuse alarm beep Mishandling Internal fuse must be changed by a qualified person ref 054653 80A 11 The device doesn t display anything...

Страница 10: ...u 15 12 2004 03 05 1989 Dieses Ger t stimmt daher mit den erweiterten Normen berein EN 60335 2 29 EN 55014 1 EN 55014 2 EN61000 3 2 EN61000 3 3 EN62233 CE GS Kennzeichnung 2016 ATTESTACION DE CONFORMI...

Страница 11: ...r manual Achtung Lesen Sie die Betriebsanleitung Cuidado Leer el manual de instrucci n antes del uso Let op Lees aandachtig de handleiding voor gebruik T 10A FUSE 80A Assurer une a ration suffisante p...

Страница 12: ...a Nominale laad capaciteit 10 600 Ah Nombre de cellules Number of cells Anzahl der Zellen Cantidad de c lulas Aantal cellen 6 12V Consommation Batteries au repos Back Current Drain R ckstrom Consumo b...

Отзывы: