16
GYSFLASH 50-12 HF
EN
Charging curve description (IU
0
I
0
U)
Test
Test
Charge
Absorption
Floating
New charge
cycle
Shorted cell
Recovery
Sulphation
Test
Desulphation
I
U
1
2
3
4
5
6
7
8
9
10
Refresh
Recovery
Phase I
Phase U
0
Phase I
0
Phase U
U=U
charge
U=U
floating
U=U
recovery
max.
T
recovery
I=I
charge
I=I
refresh
T
refresh
max.
T
desulfat
Tch
U=U
refresh
1
Battery analysis
2
Recovering damaged elements from an extended deep discharge
3
Sulphated battery test
4
Sulphated battery recovery
5
Checking the battery recovery
6
Battery charged to 80%
7
Battery charged to 100%
8
Battery cells refresh
9
Maintenance charge
10
Starts a charge cycle for maintaining performance = maintenance
To save and confirm the new settings, select “ADVANCED MENU” | save? Yes”
Push the «MODE» key to exit the «Configuration» menu.
MODE
PROTECTIONS
This device is protected against short-circuits and polarity inversions. It has an anti-spark feature which prevents sparks whilst
connecting the Gysflash to the battery. The Gysflash will not deliver current if there is no battery detected (no voltage in the clamps).
The charger is fitted with an internal 80A fuse (ref. 054653), to protect against misuse.
TROUBLESHOOTING
TROUBLESHOOTING
CAUSES
REMEDIES
1
Screen flashing :
« #error (+)<-->(-) »
+ alarm beep
The polarity has been reversed on the clamps
Connect the red clamp to the (+) and the black clamp to the (-) of the battery.
2
Screen flashing :
« #erreur U>Umax »
+ alarm beep
Battery voltage too high
Charger not suitable (ex: 24V battery instead of 12V battery).
3
Screen flashing :
« #battery error »
+ alarm beep
Battery short-circuited or damaged
Change the battery.
Battery not connected or clamps in short-circuit
Check clamps connection.
6V Battery connected
Charger not suitable.