15
PROTECTION
These devices are protected against short-circuits, polarity inversions and engine starts. They have
an anti-spark feature which prevents sparks whilst connecting the Gysflash to the battery. The
Gysflash will not deliver current if there is no battery detected (no voltage in the clamps). The charger
is protected with an internal 40A fuse (ref. 051386), against mishandling.
TROUBLESHOOTING
ANOMALIES
CAUSES
REMEDIES
1
Display flashing :
"
#error (+)
(-)
"
+ warning sound
Polarity reversal of the clamps
Connect the red clamp on (+) and the black
clamp on (-) of the battery
2
Display flashing :
"
#error U>16V
"
or
"
#error U>31V
"
+ warning sound
The battery voltage is too high
Charger not compatible or not set up in 12V for
a 24V battery
3
Display flashing :
"
#error battery
"
+ warning sound
Battery is in short-circuit or
damaged
Replace the battery
Battery not connected or clamps in
short-circuit
Check the clamps are correctly connected
Battery 6V connected
Charger not compatible