![GYS 062054 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/gys/062054/062054_manual_2281108024.webp)
24
PROTIG 161 DC HF
EN
COMPATIBLE TORCHES
L
DB
P
L
DB
P
L
DB
P
The PROTIG 161 DC is not
compatible with torches with
potentiometer.
TORCHES AND TRIGGER BEHAVIOUR
For the 1 button torch, the button is called the «main button».
For the 2 buttons torch, the first button is called «main button» and the second button is called «secondary button».
2T MODE
t
t
t
t
t
t
T2
T1
Main button
T3
T1
Main button
T2
T4
T3
T1
Main button
T2
T4
Secondary button
or
>0.5s
<0.5s
<0.5s
T1 - The main button is pressed, the welding cycle starts (PreGas,
I_Start, UpSlope and welding).
T2 - The main button is released, the welding cycle is stopped (DownS
-
lope, I_Stop, PostGas).
For the double button torch and in 2T mode only, the secondary button
works like the main button.
4T MODE
t
t
t
t
t
t
T2
T1
Main button
T3
T1
Main button
T2
T4
T3
T1
Main button
T2
T4
Secondary button
or
>0.5s
<0.5s
<0.5s
T1 - The main button is pressed, the cycle starts at PreGas and stops in
the I_Start phase.
T2 - The main button is released, the cycle continues in UpSlope and in
welding.
T3 - The main button is pressed, the cycle switches to DownSlope and
stops in I_Stop.
T4 - The main button is released, the cycle ends with PostGas.
For the dual-button torch, the secondary button is inactive.
4T MODE log
t
t
t
t
t
t
T2
T1
Main button
T3
T1
Main button
T2
T4
T3
T1
Main button
T2
T4
Secondary button
or
>0.5s
<0.5s
<0.5s
T1 - The main button is pressed, the cycle starts at PreGas and stops in
the I_Start phase.
T2 - The main button is released, the cycle continues in UpSlope and in
welding.
LOG: this mode is used during welding:
- A brief press of the main button (<0.5s), the current switches from I
welding current to I cold and vice versa.
- the secondary button is kept pressed, the welding current switches
from I welding current to I cold
- the secondary button is kept released, the welding current switched
from I cold to I welding current.
T3 – A long press on the main button (>0.5s), the cycle swicthes to
DownSlope and stops in the I_Stop phase.
T4 - The main button is released, the cycle ends with PostGas.
For the dual button torches the «up» trigger keeps the same function as the single button or trigger torch. The «down» button can, when pressed,
switch to the cold current.
Содержание 062054
Страница 2: ...2 PROTIG 161 DC HF I N V E R T E R W E L D E R JOB A A FIG 2 1 2 3 4 7 5 6 1 2 3 4 6 7 5 FIG 1...
Страница 52: ...52 PROTIG 161 DC HF RU 10 40 C 14 104 F 20 55 C 4 131 F 50 40 C 104 F 90 20 C 68 F 1000 3280 10...
Страница 53: ...53 PROTIG 161 DC HF RU 11 2 A Zmax 0 404 IEC 61000 3 11 C CEI 61000 3 12 EMF...
Страница 54: ...54 PROTIG 161 DC HF RU EMF b c d e f g h 10 CISPR 11 2009 a b c d e...
Страница 55: ...55 PROTIG 161 DC HF RU f 10 IP21 12 5 2 FIG 1 DC MMA MMA 1 5 2 6 3 7 4 IHM FIG 2 1 5 2 6 3 7 4...
Страница 64: ...64 PROTIG 161 DC HF RU DC 2...
Страница 94: ...94...
Страница 95: ...95...
Страница 96: ...GYS 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex France...