21
CUTTER 45 CT
EN
PROTECTIONS
Intervention on the torch
The operator will have to manipulate and open the torch and its accessories (change of consumables, disconnection of the torch).
If the Plasma cutter is switched on during intervention, the screen will display «stop caused by intervention on the torch» (FIG 2 - 2)
meaning that the machine has detected an intervention and that it can be carried out safely.
When the torch and / or consumables are reassembled, the message disappears and the cutter is operational again.
If the product is functional (cutting) but this problem persists, make sure to have the product checked by the after-sales service.
Insufficient air pressure
«Insufficient pressure» indicator (FIG 2 - 10) lights up if the pressure is too low for proper operation or the air is not connected to
the cutter.
Reconnect the air to the compressed air connection (FIG 1 - 9) at the rear of the product, if the message remains, press the «test
and adjust the air pressure» button (FIG 2 - 11 ) and turn the pressure control knob (FIG 1 - 3) until the air pressure is in accordance
with the intended use (see paragraph «Adjusting the air pressure»)
Thermal protection
In case of overheating (due to duty cycle and operational factors, or prolonged use at a temperature higher than 40 °), the Plasma
cutter will stop operating to cool down
The thermal protection indicator (FIG 2 - 1) lights up to indicate that the interruption is due to overheating. The indicator goes off
and the machine is ready to use again.
Disruption of normal operations.
TROUBLESHOOTING
Errors display
SYMPTOMS
POSSIBLE CAUSES
SOLUTIONS
Torch intervention
Pluged torch
Check & re-plug the torch.
Consomables disassembled
Check the presence of all consumables
and the tightening of the nozzle
Consumables issue
The electrode is not in contact with the
nozzle
Check the presence of all consumables,
replace them if necessary and restart
The electrode can not retract
Check that the electrode is not weld
to the nozzle, check that the electrode
is mobile, change the consumables if
necessary
Air pressure too low
The air pipe is not connected or the pres-
sure is too low
Check the connection of the air pipe,
start the compressor, check the inlet
pressure of the plasma cutter
Thermal protection
Intensive use (non-compliance with speci-
fied operating factors)
Leave the machine switched for it to
cool down and wait for the thermal
fault LED to disappear
The vents are blocked or the product is
placed in a confined space
Improve the environment to ensure
good ventilation
Overvoltage
A voltage too high might damage the
product.
Check the installation by an electrician
under voltage
The voltage is too low to keep satisfy
result
Phase missing
One phase is missing
Fan issue
The fan does not function
Check for foreign objects that prevent
normal rotation of the fan
The fan is not running at the right speed.
Check the connectors, replace the fan
if necessary
No current established
There is no contact between the elec-
trode and the tip
Check that the consumables are in
place and in a good shape. Replace
them if necessary. Restart the machine
and try again.
Power relay fault.
The power relay does not closed.
Return the product for repair
Содержание 013629
Страница 2: ...2 CUTTER 45 CT FIG 1 FIG 2 1 11 2 3 5 4 6 7 8 10 9 12 Mati re paisseur mm 1 5 6 8 4 10 2 7 9 3...
Страница 43: ...43 CUTTER 45 CT RU 10 40 C 14 104 F 20 55 C 4 131 F 50 40 C 104 F 90 20 C 68 F 1000 3280 10...
Страница 44: ...44 CUTTER 45 CT RU 11 2 A CEI 61000 3 11 CEI 61000 3 12 EMF EMF...
Страница 45: ...45 CUTTER 45 CT RU b c d e f g h 10 CISPR 11 2009 a b c d e f 10...
Страница 49: ...49 CUTTER 45 CT RU 6 m 5 2 bar 75 Psi 12 m 5 5 bar 80 Psi 20 50 A 20 50 A FIG 2 8 1 2 3...
Страница 50: ...50 CUTTER 45 CT RU 1 90 2 3 1 30 2 30 90 3 4...
Страница 51: ...51 CUTTER 45 CT RU FIG 2 2 FIG 2 10 FIG 1 9 FIG 2 11 FIG 1 3 40 FIG 2 1...
Страница 52: ...52 CUTTER 45 CT RU 3 039728 2...
Страница 78: ...78 GYS SAS 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex FRANCE...