background image

5

Function Buttons

Press this button to turn the multimeter on and off.

Press this button to set configure the RPM to read in 2 
Cycle or 4 Cycle mode.  Distributorless Ignition Systems 
should be set to 2 Cycle mode to correctly read RPM.

Press this button to freeze and unfreeze the display.  

Pressing  the  Min/Max  button  while  in  certain  tests 

will  have  set  up  the  meter  to  capture  minimum  and 
maximum  readings.    Continue  to  press  this  button  to 
view the min and max readings on the top display.  Press 

any other test button to stop capturing minimums and 
maximums.

Press  the  Range  button  to  manually  set  the  range  of 
most tests.  Press any other test button to return to auto 
ranging.

Press the REL Zero button to zero out the reading on the 
bottom display.  Use this button to zero the low and high 
amps probe, or zero out the ohm meter.  This function 
can also be used to set a base measurement as zero.  
Then all readings will be +/- from the base reading.

ON

OFF

2C/4C

HOLD

Min

Max

Range

REL

Zero

Содержание Ferret 95

Страница 1: ...1 Operator s Manual Automotive Analyzer It s More than a Multimeter...

Страница 2: ...5 REL Zero 5 Key Combinations Special Functions 6 Backlight Control 6 Power up Status 6 Software Version 6 Volts 7 Ohms 8 Amps 9 Lo Amps 10 Volts Amps 11 Time 12 Fuel 13 Coil 14 KV Test Instructions...

Страница 3: ...uel Pump RPM 4 Ranges RPM Dwell Milliseconds 1 Range 0 to 100 Peak Amps 1 Range 0 to 20 0 Amps Build Time 1 Range 0 200 mSec Drive Time 1 Range 0 200 mSec KiloVolts Optional 1 Range 0 40 0 kV Operatin...

Страница 4: ...ing the protective boot to the front panel Remove the front panel On the back of the display board located at the bottom of the board is the primary battery location This position must be filled with...

Страница 5: ...maximum readings Continue to press this button to view the min and max readings on the top display Press any other test button to stop capturing minimums and maximums Press the Range button to manuall...

Страница 6: ...us Press the Volts and V A buttons at the same time to disable the auto power off function Turn the unit off then back on The meter will remain on until you turn it off or the batteries run down Softw...

Страница 7: ...rate measurements of irregular shaped AC waveforms The Peak to Peak function is the best measurement tool to determine the amplitude of any signal Note AC auto ranging takes more time to occur than DC...

Страница 8: ...l measure semiconductor junction voltages up to 1 999 In the reverse direction an OFL indication is expected The continuity test indicated by both the beeper symbol and the Ohms symbol being active us...

Страница 9: ...up to 600 Amps The AC functions use a certified true RMS chip to provide accurate interpretations of AC waveforms The Peak to Peak function not shown is the best measurement tool to determine the ampl...

Страница 10: ...measure from 10 milliamps to 20 Amps The AC functions use a certified true RMS chip to provide accurate interpretations of AC waveforms The Peak to Peak function is the best measurement tool to determ...

Страница 11: ...ltage on the bottom display The Battery Starter Test will display a Crank Engine message CrnEng To set up the test connect the test leads to the vehicle battery terminals and place the Amp Probe onto...

Страница 12: ...njector The Pulse Width and Dwell milliSecond tests both display in milliSeconds however the Pulse Width test is optimized for non ignition signals and the Dwell millisecond test is optimized for igni...

Страница 13: ...lected The RANGE key cycles through the commutator settings Most pumps have 6 or 8 communtators Consult a technical information source for the correct commutator count Each time the RANGE key is press...

Страница 14: ...KV peaks are displayed on the lower display The BARGRAPH indicates activity of the KV input between numerical updates See the expanded section on KV to learn more When using the Differential RPM test...

Страница 15: ...tton three times If KV is low for one or more cylinders the cause could be Open Plug Wire at the Coil KV will be very low downstream of the open Narrow or Fouled Plug Gap Rich Mixture If KV is High fo...

Страница 16: ...that is stuck Longer build time could be from a bad driver or wire connection Drive Time is the time the injector is actively driven Use momentary wide open throttle to see the Min and Max readings A...

Страница 17: ...ction from the ignition module to the coil Short Build Time may be caused by a shorted coil Build Time will be slightly longer during cranking Engine Peak Build Engine Peak Build Company Amps mSec Com...

Страница 18: ...N X008 01 Reads RPM by connecting to any spark plug wire 5 feet long Test Clip Black P N S011 30 Test Clip Red P N S011 32 Plugs into the end of the test lead Large jaw opening makes it easy to connec...

Страница 19: ...n COP and inter nal coil ignition KV Adapter P N X095 K0 Plugs into the Tach jack on the me ter and provides a Y adapter so you can connect the spark pickup to read RPM while you are also read ing ign...

Страница 20: ...ems such as NOx Sensors Oxygen Sensors and paper is not covered by warranty GxT Inc s sole liability and buyer s exclusive remedy is limited to repair or replacement of the product as stated in the Li...

Страница 21: ...sparks to ignite gas or even weld tools into a battery short circuit c Keep the space around a battery well ventilated d Do not make sparks or allow flames near batteries Before working on a vehicle...

Страница 22: ...22 Notes...

Страница 23: ...23 Notes...

Страница 24: ...24 Copyright 2006 GxT Inc Cheboygan Michigan USA E095 01...