background image

18

Parts & Accessories

Test Lead, P/N W090-92

6 foot Shielded Test lead.  BNC connector 
at one end, and banana jacks at the other 
end.

Lo Amps Probe, P/N X926-00

Reads  from  10  milliamps  to  20  amps 
inductively.  5 Feet long.

Hi Amps Probe, P/N X000-02

Reads from 1 amp to 600 amps inductively.  
5 Feet long, opening is large enough to go 
around 00 cable.

Spark Pickup, P/N X008-01

Reads  RPM  by  connecting  to  any  spark 
plug wire.  5 feet long.

Test Clip, Black, P/N S011-30
Test Clip, Red, P/N S011-32

Plugs into the end of the test lead.  Large 
jaw  opening  makes  it  easy  to  connect  to 
the battery, or ground for testing.

Test Prod, Black, P/N S011-20
Test Prod, Red, P/N S011-22

Plugs into the end of the test lead.  Needle 
tip makes it easy to probe wires, or perform 
pinpoint testing.

BNC Adapter, P/N S013-05

Adapts the meter to allow the connection 
of any standard banana jack inputs, such 
as  third  party  temperature  or  pressure 
transducers.

Содержание Ferret 95

Страница 1: ...1 Operator s Manual Automotive Analyzer It s More than a Multimeter...

Страница 2: ...5 REL Zero 5 Key Combinations Special Functions 6 Backlight Control 6 Power up Status 6 Software Version 6 Volts 7 Ohms 8 Amps 9 Lo Amps 10 Volts Amps 11 Time 12 Fuel 13 Coil 14 KV Test Instructions...

Страница 3: ...uel Pump RPM 4 Ranges RPM Dwell Milliseconds 1 Range 0 to 100 Peak Amps 1 Range 0 to 20 0 Amps Build Time 1 Range 0 200 mSec Drive Time 1 Range 0 200 mSec KiloVolts Optional 1 Range 0 40 0 kV Operatin...

Страница 4: ...ing the protective boot to the front panel Remove the front panel On the back of the display board located at the bottom of the board is the primary battery location This position must be filled with...

Страница 5: ...maximum readings Continue to press this button to view the min and max readings on the top display Press any other test button to stop capturing minimums and maximums Press the Range button to manuall...

Страница 6: ...us Press the Volts and V A buttons at the same time to disable the auto power off function Turn the unit off then back on The meter will remain on until you turn it off or the batteries run down Softw...

Страница 7: ...rate measurements of irregular shaped AC waveforms The Peak to Peak function is the best measurement tool to determine the amplitude of any signal Note AC auto ranging takes more time to occur than DC...

Страница 8: ...l measure semiconductor junction voltages up to 1 999 In the reverse direction an OFL indication is expected The continuity test indicated by both the beeper symbol and the Ohms symbol being active us...

Страница 9: ...up to 600 Amps The AC functions use a certified true RMS chip to provide accurate interpretations of AC waveforms The Peak to Peak function not shown is the best measurement tool to determine the ampl...

Страница 10: ...measure from 10 milliamps to 20 Amps The AC functions use a certified true RMS chip to provide accurate interpretations of AC waveforms The Peak to Peak function is the best measurement tool to determ...

Страница 11: ...ltage on the bottom display The Battery Starter Test will display a Crank Engine message CrnEng To set up the test connect the test leads to the vehicle battery terminals and place the Amp Probe onto...

Страница 12: ...njector The Pulse Width and Dwell milliSecond tests both display in milliSeconds however the Pulse Width test is optimized for non ignition signals and the Dwell millisecond test is optimized for igni...

Страница 13: ...lected The RANGE key cycles through the commutator settings Most pumps have 6 or 8 communtators Consult a technical information source for the correct commutator count Each time the RANGE key is press...

Страница 14: ...KV peaks are displayed on the lower display The BARGRAPH indicates activity of the KV input between numerical updates See the expanded section on KV to learn more When using the Differential RPM test...

Страница 15: ...tton three times If KV is low for one or more cylinders the cause could be Open Plug Wire at the Coil KV will be very low downstream of the open Narrow or Fouled Plug Gap Rich Mixture If KV is High fo...

Страница 16: ...that is stuck Longer build time could be from a bad driver or wire connection Drive Time is the time the injector is actively driven Use momentary wide open throttle to see the Min and Max readings A...

Страница 17: ...ction from the ignition module to the coil Short Build Time may be caused by a shorted coil Build Time will be slightly longer during cranking Engine Peak Build Engine Peak Build Company Amps mSec Com...

Страница 18: ...N X008 01 Reads RPM by connecting to any spark plug wire 5 feet long Test Clip Black P N S011 30 Test Clip Red P N S011 32 Plugs into the end of the test lead Large jaw opening makes it easy to connec...

Страница 19: ...n COP and inter nal coil ignition KV Adapter P N X095 K0 Plugs into the Tach jack on the me ter and provides a Y adapter so you can connect the spark pickup to read RPM while you are also read ing ign...

Страница 20: ...ems such as NOx Sensors Oxygen Sensors and paper is not covered by warranty GxT Inc s sole liability and buyer s exclusive remedy is limited to repair or replacement of the product as stated in the Li...

Страница 21: ...sparks to ignite gas or even weld tools into a battery short circuit c Keep the space around a battery well ventilated d Do not make sparks or allow flames near batteries Before working on a vehicle...

Страница 22: ...22 Notes...

Страница 23: ...23 Notes...

Страница 24: ...24 Copyright 2006 GxT Inc Cheboygan Michigan USA E095 01...