PEL-2000 Series User Manual
94
To recall saved files, the reverse is not true. Files
must be recalled to each channel separately.
File Format
Single Channel Filename format
Memory data
Preset data
SEQ data
1: PEL series Load module
type:
2020 = PEL-2020
2030 = PEL-2030
2040 = PEL-2040
2: Channel
R = Right
L = Left
0 = Single channel or
not used
3: Save file number:
0 ~99
Incremented after each
consecutive save.
4: File extension
M = Memory data
P = Preset data
A= SEQ data