TEST MODE FUNCTION
177
Manage Simulation Settings
Simulation settings can be easily saved to or from a USB flash drive
using the Save/Recall Files utility in the Menu system. Files can
also be deleted from local memory using the utility.
File Format
When files are saved to USB they are saved in
the following format:
SIMX. SIM, where X is the memory number
0 ~ 9 (SIM0 ~ SIM9). The files are saved to
USB:/gw.
When files are recalled from USB, files must be
recalled from the same memory number. For
example, the file sim0.sim can only be recalled to
memory number SIM0. The files can only be
recalled from the USB:/gw directory.
Steps
1.
Press the
Menu
key. The Menu
settings will appear on the display.
2.
Use the scroll wheel to go to item 10,
Save/Recall
Files
and press
Enter
.
3.
Go to the
Type
setting using the scroll wheel
and press
Enter
. Select
SIMULATE
and press
Enter
to confirm.
4.
Go to the
Action
setting and choose the file
operation and then press
Enter
.
MEM
USB
Saves the selected simulation
memory from the local memory
to a USB flash drive.
MEM
USB
Loads the simulation memory
from a USB flash drive to the
selected local memory.
Содержание ASR-3000 Series
Страница 1: ...Programmable AC DC Power Source ASR 3000 Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 11: ...GETTING STARTED 11...
Страница 12: ...ASR 3000 Series User Manual 12...
Страница 13: ...GETTING STARTED 13...
Страница 134: ...ASR 3000 Series User Manual 134 Example Power ON setting...
Страница 226: ...ASR 3000 Series User Manual 226 ASR 3000 Dimensions ASR 3200 3300 3400 3400HF Scale mm...