ASR-3000 Series User Manual
158
Secondary
settings
CT (Constant), KP (Keep), SP
(Sweep)
Note: Step 0 can only be set to
either CT or SP.
8.
Go to the
DCV
setting and set the output
voltage for the step. If you input a DCV value
that is not within the voltage range, the
warning message below will be shown.
Next set the secondary voltage settings to
determine characteristics of the voltage output.
DCV
0.0 ~ 570.0V (Range 200V)
0.0 ~ 285.0V (Range 100V)
Secondary
settings
CT (Constant), KP (Keep), SP
(Sweep)
Note
Step 0 can only be set to either CT or SP.
Note
ACV setting range varies when Wave is TRI or
ARB1~16. The setting range is 0~570 Vpp or 0~1140
Vpp when V Unit is set p-p.
9.
Go to the
Fset
setting and set the frequency of
the step. If you input a frequency value that is
not within the range, the warning message
below will be shown.
Fset
1.0 ~ 999.9Hz