Product Features 

 

High contrast color TFT LCD display supports resolution up to SVGA 800x600. 
Compatible with IBM VGA and VESA. 

 

Power management system conforms to VESA DPMS standard. 

 

Universal power adapter. 

 

Detachable stand for wall-mounting application. 

 

IP54 compliant front cover, which is dust-resistant and waterproof. 

 

Fully tempered glass serves as a standard module. 

 

Optional imbedded audio system. 

 

Optional MSR holder. 

 

Optional video-in function. 

 

Optional touch screen function. 

 

Package Contents 

Included with your LCD monitor are following items: 

 

12.1” TFT liquid crystal monitor 

 

D-sub 15 pin signal cable 

 

Power adapter  

 

Power cord 

 

User’s manual 

 

Audio cable (option) 

 

Video signal cable (option) 

 

RS232 cable for touch screen (option) 

 

Cleaning 

 

Gently wipe the screen with a clean camel hair lens brush, or a soft, clean, lint-free cloth. 
This removes dust and other particles that can scratch the screen. 

 

Do not apply pressure to the screen surface when wiping it clean. 

 

Do not pour or spray any liquid directly onto the screen or case of the LCD monitor. 
Chemical cleaners have been reported to damage the screen or case of the LCD monitor. 

 
Taking a Look 

Front View      
              

   

   

 

1. 

Power Switch

    Pressing this button turns the display system power 

on

 or 

off

2. 

Power LED

    This LED indicates different status when this unit operates in different 

modes. 

Содержание P12AS-L

Страница 1: ... controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation If the product has been dropped or the cabinet has been damaged If the product exhibits a distinct change in performance indicating a need for service Power and extension cords Do not allow anything to rest on the power cord Do not locate this product where pers...

Страница 2: ... of the FCC Rules Operation is subject to the following two conditions 1 This device may cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Notice The use of non shielded interface with this equipment is prohibited If necessary the user should consult the dealer or an experienced radio television technician for a...

Страница 3: ...id crystal monitor D sub 15 pin signal cable Power adapter Power cord User s manual Audio cable option Video signal cable option RS232 cable for touch screen option Cleaning Gently wipe the screen with a clean camel hair lens brush or a soft clean lint free cloth This removes dust and other particles that can scratch the screen Do not apply pressure to the screen surface when wiping it clean Do no...

Страница 4: ...ion is off for model with video in function only 7 MSR Magnetic Strip Reader Holder optional module Setting Up WARNING When you disconnect the cord cables be sure to hold the connector instead of the wire part Touch Screen Model Analog Video in Model 1 Connect one end of the power adapter to the monitor and the other end to the connector of the power cord 2 Connect one end of the signal cable to t...

Страница 5: ...tton on front panel turns the display system power on Display Angle Tilting For viewing clarity you can tilt the monitor down to 5 degrees or up to 60 degrees CAUTION In order to protect the LCD be sure to hold the base when you adjust the LCD and do not touch the screen OSD Control Options OSD Main Menu OSD Main Menu video in function VOLUME optional module Adjust the speaker volume using and but...

Страница 6: ...e 1 Select one display pattern from your computer 2 Use and buttons on the LCD monitor to decrease the vertical interference to get the optimal display PHASE This item is used to decrease the horizontal interference 1 Select one display pattern from your computer 2 Use and buttons on the LCD monitor to decrease the horizontal interference to get the optimal display TRACK Adjust the track using and...

Страница 7: ...preset values Troubleshooting The monitor does not respond after you turn on the system Check if the Power Switch of monitor is turned on Turn off the power and check the monitor s power cord and signal cable for proper connection The characters on the screen are dim Refer to the Controls and Adjustments section to adjust the brightness The screen is blank During operation the monitor screen may a...

Страница 8: ...SA85 43 269 85 008 9 800X600 SVGA 35 156 56 250 10 800X600 SVGA 37 879 60 317 11 800X600 VESA72 48 077 72 188 12 800X600 VESA75 46 875 75 000 13 800X600 SVGA 53 674 85 061 Specifications Display 12 1 TFT Active Matrix Panel Display Size 246 H x 184 5 V mm Pixel Pitch 0 3075 H x 0 3075 V mm Display Mode VGA 640 x 350 70 85Hz VGA 720 x 400 70 85Hz VGA 640 x 480 60 72 75 85Hz SVGA 800 x 600 56 60 72 ...

Страница 9: ...W Per channel Touch Panel option Resistive Capacitive Type with RS232 connector Video in option S and RCA connectors Power Adapter Input AC 100 240V 50 60Hz Output DC 12V 2 5A min Limited power source LPS MSR Holder option 88 H x 30 W mm Operating Conditions Temperature 5o C 35o C 41o F 95o F Humidity 20 80 No Condensation Altitude To 10 000 Feet Storage Conditions Temperature 20o C 60o C 4o F 140...

Отзывы: