II - TECHNICAL PARAMETERS AND MAIN CHARACTERISTICS
Technical parameters
Voltage
AC 230V, 50-60Hz
Amperage
3 A
Working environment
5ºC ~99ºC
Consumption
<0.3 W
Protection index
IP20
Programmable temperature
5ºC e 35ºC
Temperature control precision
0.5 ºC
Main characteristics
Programs
6 daily, 3 weekly
Probe reading options
3 (internal, external and both)
External dimensions
86mm x 86mm x 17mm
Material
PC + ABS
Screen background color
Blue
Memory in case of electrical failure
Time and Programs
Child lock
Yes
Installation
Wall-Inserted Type
IV - INSTALLATION
1. Separate the thermostat from the display using a screwdriver to press the
groove at the back of the thermostat and pushing the display upwards (fig.1).
2. Follow the wiring diagram (fig. 2) to connect the power, the electrovalve
and the floor probe.
3. Use the two screws provided to fix the outer ring and the thermostat base
to the electrician's deep box previously installed (fig. 3) and make sure that it
is properly installed.
4. Attach the display to the four projections on the mounting plate and push it
downwards (never press the LCD display directly). The installation is complete.
Turn on the power to test the thermostat.
ATTENTION!
When being installed, this thermostat may cause an
electric shock. Make sure the installation is done by
a qualified electrician.
III - CAUTIONS FOR INSTALLATION
1. Installation should only be done when the electric supply is off, otherwise it can
damage the thermostat and cause an electric shock.
2. Choose the most suitable location for installing the thermostat (about 1,60m
above the floor). It must not be installed at eye level.
3. Installation should not be made at altitudes higher then 2000m above sea level.
Fig. 1 - Thermostat opening
Fig. 2 - Wiring diagram
Fig. 3 - Thermostat Installation
V - THERMOSTAT INTERFACE
SET TEMP
Anti-Frozen
Manual Mode
Heating
Child Lock
Room Temp.
Floor Temp.
Clock
On / Off
Menu
Time Setting
Increase / Decrease
Period
Week
Set temperature
Turn On/Off
Short press: Toggles between manual and automatic mode
Long press: Enter programming settings
Time and Day of the week settings
Increases Value
Decreases Value
Button functions
VI - THERMOSTAT PROGRAMMING
»
TURN ON/OFF
Press the button to turn on the thermostat.
Press the button again to turn off the thermostat.
Dear User:
Congratulations on choosing a thermostat. Please refer to this user
manual before installing/using the thermostat.
This thermostat is used to control the temperature of hidraulic underfloor
heating in a given room, wether in a domestic, commercial or industrial
environment.
While we try to provide the best device possible, we are always available for
technical support. If you have any questions, please contact us.
ElectroValve
3A
N (Neutral Wire)
L (Live wire)
AC220V, 50~60Hz
Floor Sensor
1 2 3 4
5
N
L
6
NTC
IP 20
AC230V imax:3A
close
open
M