SETTING THE TIME AND DAY OF THE WEEK
With the thermostat on, press the button . The Hour digits will blink. Use
the + and - buttons to set the time.
Press the button again to move to the minutes and use the + and -
buttons to set the minutes.
Finally press the button again and the day of the week will flash, with
the number 1 representing Monday, 5 representing Friday, 6 representing
Saturday and 7 representing Sunday.
»
TOGGLE BETWEEN MANUAL AND AUTOMATIC MODE
With the thermostat on, press the button quickly to switch between
manual and automatic mode. In manual mode you will see the symbol on
the display and in automatic mode you will see the programming that is
active ( ).
»
SET TEMPERATURE IN MANUAL MODE
With the thermostat turned on in manual mode, use the + and - buttons to set
the temperature.
The thermostat turns on when the temperature of the probe is lower than the
one set at 1.5ºC and the symbol appears on the screen. This symbol means
that the cable or network is heating up. The thermostat switches off when the
probe temperature is higher than the one set at 1ºC.
»
DAILY AND WEEKLY SCHEDULE
This thermostat supports 6 daily and 3 weekly programs (6 programs from
Monday to Friday and two programs for Saturday and Sunday, or 6 programs
from Monday to Saturday and two for Sunday or 6 programs from Monday to
Sunday).
Press the button for 5 seconds and you will see the days of the week (
), use the + and - buttons to select the type of programming you
desire:
- : 6 programs for the week plus 2 programs for the weekend
- : 6 programs from Mon. to Saturday plus 2 programs for Sunday
- : 6 programs from Monday to Sunday.
Press the button again quickly and you will have the temperature of the
first weekly program ( ) flashing, use the + and - buttons to set the tempera-
ture.
If you want to change the start time of the program press the button and
you will see the hour digits flashing, use the + and - buttons to set the time.
Press the button again and the minute digits will flash, use the + and -
buttons to set the program start minutes. Press the button again to return
to the temperature.
Press the button quickly to go to the next program and repeat the process
until all the programs are defined.
NOTE 1: Daily schedules are sequential, so if the first program has been
programmed to start at 10:00 , the second cannot start at 09:00.
NOTE 2: There is no opening and closing of the daily programming period. If
you do not want heating for some time, you must set a temperature low
enough so that the thermostat does not start.
NOTE 3: During programming, if you do not press any button for 15 seconds,
you will exit programming mode.
NOTE 4: When the thermostat is operating in automatic mode, you can
manually change the temperature set for that daily period using the + and -
buttons. The symbol will flash. Changes made manually while in
automatic mode are canceled when is started a new daily period.
»
CHILD LOCK
With the thermostat on, press the button for 5 seconds to lock / unlock the
thermostat.
Period
Icon
Default Time
Default Temperature
Week
Weekend
1
2
3
4
5
6
1
2
06:00
08:00
11:30
12:30
17:30
22:00
08:00
23:00
20 ºC
15 ºC
15 ºC
15 ºC
22 ºC
15 ºC
22 ºC
15 ºC
VIII - ADVANCED SETTINGS
With the thermostat turned off, keep the button - pressed and press the
button to enter the advanced settings menu. Press the button to
move to the next settings.
»
SEN - PROBE SELECTION
This configuration allows you to choose which probe or probes to use, with 00
being the ambient probe, 01 the floor probe and 02 both probes. The factory
setting is 00. Use the + and - buttons to define the probe to be used.
If option 02 is set (both probes in use), the thermostat display in normal
operation shows only the temperature of the ambient probe. To check the
temperature of the floor probe, keep the button pressed and simultane-
ously press the button .
»
OSV - FLOOR PROBE LIMIT TEMPERATURE
This function allows you to configure the temperature limit of the floor probe.
This value defines a safety temperature, from which the thermostat switches
off, regardless of its programming.
This setting only takes effect if both probes are being used.
Use the + and - buttons to set the value that can range from 5ºC to 99ºC. The
factory set value is 42ºC.
»
DIF - TEMPERATURE DIFFERENTIAL ASSOCIATED WITH THE LIMIT OF THE
FLOOR PROBE
This function allows you to configure the temperature differential associated
with the limit of the floor probe. For example, if you have set a value of 2ºC in
this option and set 40ºC in the previous function, the thermostat will switch
off at 42ºC and switch on again at 38ºC. Use the + and - buttons to set the
value that can range from 1ºC to 9ºC. The factory set value is 2ºC.
»
SVH - HIGH TEMPERATURE LIMIT FOR ROOM TEMPERATURE
This function allows you to configure the high temperature limit of the
ambient probe. The thermostat switches off when the ambient probe reaches
this temperature. Use the + and - buttons to set the value that can range from
5ºC to 99ºC. The factory-set value is 35ºC.
»
SVL - LOW TEMPERATURE LIMIT FOR ROOM TEMPERATURE
This function allows you to configure the low temperature limit of the
ambient probe. The thermostat switches off when the ambient probe reaches
this temperature. Use the + and - buttons to set the value that can range from
5ºC to 99ºC. The factory set value is 5ºC.
»
ADJ - CORRECTION OF THE AMBIENT PROBE TEMPERATURE
This function allows to correct the temperature of the ambient probe. This
correction is applied when the temperature displayed by the room probe is
not equal to the actual room temperature (measured with another external
device). This can happen due to the installation or position of the thermostat.
Use the + and - buttons to set the value. The factory-set value is 0ºC.
»
FRE - ANTI-FROZEN
This function allows to activate or deactivate the anti-frozen function. With
this function active, the thermostat starts automatically when the tempera-
ture of the ambient probe is below the low temperature limit defined in the
SVL function. A value of 0 means that the function is off and a value of 1
means that the function is on. The factory setting is 0.
»
PON - MEMORY FUNCTION IN CASE OF POWER FAILURE
This function allows you to define whether or not the thermostat should
memorize its settings in the event of a power failure. A value of 0 means that
the function is off and a value of 1 means that the function is on. The factory
setting is 0.
»
FAC - DEFINIÇÕES DE FÁBRICA
This function allows you to reset all settings and functions to the factory
values. Use the + and - buttons to set the value. 00 will reset all values to
factory defaults. If you do not want to make changes, select the value 08.
Erro
Cause
Solution
ERR
Floor probe error
Replace floor probe
IX - ERROR TABLE
GLOBOVAC Ltd.
Address:
Globovac Ltd, 8C Castle Road, Chelston
Business Park, Wellington, Somerset
TA21 9JQ, United Kingdom
Tel Export:
+44 (0) 1293 768 210
Tel UK Costumers:
+44 (0) 1293 772 165
Email:
Web:
www.globovac.com