DUCTING VERSION
In this case the fumes are conveyed outside of the building by means of a special pipe connected with
the connection ring located on top of the hood.
Attention! The exhausting pipe is not supplied and must be purchased apart. Diameter of the exhaust-
ing pipe must be equal to that of the connection ring.
In the horizontal runs the exhausting pipe must be slightly slanted (about 10°) and directed upwards to
vent the air easily from the room to the outside.
Attention! If the hood is supplied with active charcoal filter, then it must be removed.
Connect the hood and discharge holes on the walls with a diameter equivalent to the air outlet (con-
nection flange).
Using the tubes and discharge holes on walls with smaller dimensions will cause a diminution of the
suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
!
Use a duct of the minimum indispensible length.
!
Use a duct with as few elbows as possible (maximum elbow angle: 90°).
!
Avoid drastic changes in the duct cross-section.
!
Use a duct as smooth as possible inside.
!
The duct must be made of certified material.
FILTER VERSION
One active charcoal filter is needed for this and can be obtained from your usual retailer.
The filter removes the grease and smells from the extracted air before sending it back into the room
through the upper outlet grid.
INSTALLATION
The minimum distance between the supporting surface for the cooking equipment on the hob and the
lowest part of the range hood must be not less than 50cm from electric cookers and 65cm from gas
or mixed cookers.
If the instructions for installation for the gas hob specify a greater distance, this must be adhered to.
ELECTRICAL CONNECTION
The mains power supply must correspond to the rating indicated on the plate situated inside the hood.
If provided with a plug connect the hood to a socket in compliance with current regulations and posi-
tioned in an accessible area, after installation. If it not fitted with a plug (direct mains connection) or if
the plug is not located in an accessible area, after installation, apply a double pole switch in accord-
ance with standards which assures the complete disconnection of the mains under conditions relating
to over-current category III, in accordance with installation instructions.
Warning!
Before re-connecting the hood circuit to the mains supply and checking the efficient func-
tion, always check that the mains cable is correctly assembled.
EN - COOKER HOOD
22
Содержание GZ 600B
Страница 1: ...GZ 600 GZ 600B...
Страница 2: ...CZ DIGESTO 7 DE DUNSTABZUGSHAUBE 13 EN COOKER HOOD 20 SK ODS VA PARY 26...
Страница 5: ...W cm 220 240V 50 60Hz W 2 cm 30 cm 1 cm 15 17 16 18 13 14...
Страница 6: ...1 4 press 11 10 12 21 19 20...
Страница 32: ...Privest s r o Na Zlatnici 301 2 147 00 Praha 4 tel 420 241 410819 email sales privest cz www guzzanti cz...