7.3.1 Emptying media
To empty machine:
•
Turn on the dust collector
•
Turn on cyclone
•
Use an air line to clean inside cabinet
•
Once clean leave dust extraction on for 10 minutes to clear pipes of residual media
•
Switch off cyclone
•
Switch off dust collector
•
Then follow the instructions below depending upon the pressure pot fitted
G27 Pressure pot
•
Unscrew media control valve and empty pot
G55 Pressure pot
•
Place container under media control valve
•
Unscrew latches and allow media control
valve to swing open
•
Collect media in container
TAKE CARE TO AVOID TRAPPING FINGERS; THE MEDIA CONTROL
VALVE COULD BE VERY HEAVY