Tess 308 Installation Manual – Issue 1 (DR1004, July 2014)                                                           Page | 4  
 

2. Tess 308 System 

 

Standard components and assemblies supplied 

 

 

Description 

 

1.

 

End Plate Sub Assemblies (Top fix shown, face fix also available) 

2.

 

Barrel Assembly  85 mm Diameter     
(including fabric if supplied  )                                       

3.

 

Motor Assembly 

4.

 

Bobbin Assembly  

5.

 

Cable Guide Retention Bracket 

6.

 

2mm Diameter Guide Wire  

7.

 

Cable Anchor Brackets 

8.

 

Hem Bar Assembly 
 

Fitting Kit to include : 

 

2mm Diameter  Aluminium Ferrule 

 

Installation Manual 

 

Motor Limit Setting Key 

 

Fixings 

Qty 

 


 



Roll Length 


 

 


See page 5 

Содержание TESS 308

Страница 1: ...Tess 308 Installation Manual Issue 1 DR1004 July 2014 Page 1 TESS 308 Installation Manual Please read these instructions in full prior to starting your installation ...

Страница 2: ...tents 1 Important information about TESS Systems 3 2 Tess 308 System 4 3 Fitting Kit 5 4 System Preparation Fabric fitting if not pre fitted 6 5 Installation 7 6 Hirschmann Fitting 12 7 Manual Motor Limits Setting 13 8 Radio Motor Limits Setting 14 9 Maintenance 16 ...

Страница 3: ...ith relevant EU regulations General certificates of conformity and declarations of performance are available on our website www guthriedouglas com Alternatively please contact us for any special local testing requirements As the product installer you are responsible for ensuring that the installed product conforms with relevant standards and legislation TESS Systems are designed to operate at temp...

Страница 4: ...n face fix also available 2 Barrel Assembly 85 mm Diameter including fabric if supplied 3 Motor Assembly 4 Bobbin Assembly 5 Cable Guide Retention Bracket 6 2mm Diameter Guide Wire 7 Cable Anchor Brackets 8 Hem Bar Assembly Fitting Kit to include 2mm Diameter Aluminium Ferrule Installation Manual Motor Limit Setting Key Fixings Qty 2 1 1 1 2 Roll Length 2 1 2 1 1 See page 5 ...

Страница 5: ...e 1 DR1004 July 2014 Page 5 3 Fitting Kit REF NO FIXING WHERE USED 1 M6 x 10 BOLT MOUNTING PLATE 2 M6 x 8 PAN HEAD MOUNTING BRACKET 3 M6 SHAKE PROOF MOUNTING PLATE 4 M6 WASHER MOUNTING PLATE 5 M6 PLASTIC TOP HAT WASHER MOUNTING BRACKET ...

Страница 6: ...ifications The fabric must have pockets as shown at each end Fabric drawing is available on request A fabric retaining rod will be supplied already fitted into the steel barrel tube remove this and insert into the fabric pocket and slide the fabric onto the barrel assembly Wind the fabric onto the barrel Remove the fabric rod from the hem bar insert into the fabric pocket and slide the hem bar int...

Страница 7: ... refer to fixing listed in the supplied fitting kit in section 3 page 5 The same fixings are required for both end plates motor and bobbin side Fit end plates and adjust the spacing so the distance between them is as ordered system width Install the barrel assembly Ensure the barrel assembly is level adjust if necessary by slackening the fixing screw 6 adjusting the tracking plates 7 ...

Страница 8: ...Tess 308 Installation Manual Issue 1 DR1004 July 2014 Page 8 5 Installation 5 2 Fit the cable retention bracket 1 using the fixings 2 and 5 supplied in the fitting kit in section 3 page 5 ...

Страница 9: ...ble crimping tool crimp the ferrule 1 to the end of the cable 2 removing the coating where the ferrule is to be crimped Ensure the ferrules are securely fixed Guide wires are required to be fitted on both end plate assemblies Insert the guide wire into the cable retention bracket Ascertain the approximate length required and cut the wire taking care not to cut too short ...

Страница 10: ...e Cable Tensioning screw 2 to the Anchor Bracket 3 and feed the guide wire through Secure the guide wire in place using the fixing screw 6 Tension the guide wire using a 11mm and 13mm spanner 11mm spanner to hold in place the tension screw 2 and the 13mm spanner to tighten the nut item 4 Once the guide wire is tight tighten the lock nut 5 to secure Cut off any excess guide wire ...

Страница 11: ...Tess 308 Installation Manual Issue 1 DR1004 July 2014 Page 11 5 Installation 5 5 Check System Width Check System Draw Check across diagonals to ensure system squareness is correct ...

Страница 12: ...Tess 308 Installation Manual Issue 1 DR1004 July 2014 Page 12 6 Hirschmann Fitting 6 1 Hirschmann Plug The diagram above shows the Hirschmann plug wiring as per Guthrie Douglas GDE50360 ...

Страница 13: ...limit by turning the limit adjuster clockwise the limit will become shorter turning the limit adjuster counter clockwise will lower the limit when lowering the limit remember to retract and deploy the system using the hand controls to ensure that the limit is correct When close to the desired position make small adjustments to the limit adjusters and retract and deploy the system away from the lim...

Страница 14: ...ly 3 seconds The motor will acknowledge Setting the end limits 1 Press and hold the down button and the motor will deploy Continue this until the required deployed position is reached use the up down buttons to achieve the correct position To memorise the fully deployed position press the stop and up button simultaneously The motor will then run automatically in the retract direction 2 When the mo...

Страница 15: ...ncelled and will have to be repeated 2 As a safety precaution use the up down button to deploy retract the system to a central position away from either pre existing limits 3 Turn off the power supply to all other motors that you do not want cancelled out of the programming Failure to do so will cancel all programmed motors 4 With the mains switch turn OFF the power supply for 2 seconds 5 Switch O...

Страница 16: ... Every 12 Months Check tracking and fabric condition creases Check that tracking is correct Make adjustments where required Check limit positions Check fabric edges for small rips cuts damage Check fixing screws Tighten any loose screws Clean and remove any debris from the system Every 10 Years additional checks Check motor operation Depending motor usage and working conditions and consider replac...

Страница 17: ...sue 1 DR1004 July 2014 Page 17 Guthrie Douglas Group Limited 12 Heathcote Way Heathcote Industrial Estate Warwick UK CV34 6TE E mail solar guthriedouglas com Web site www gdsolarcontrol com Tel 44 0 1926 310 850 Fax 44 0 1926 832 914 ...