![Guth Laboratories 2100 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/guth-laboratories/2100/2100_operation-manual_2279202015.webp)
M
O
D
EL
21
00
-
BL
O
CK
D
IA
G
RA
M
34
.0
M
U
LT
IP
LE
XE
D
D
IS
PL
AY
D
RI
VE
R
TI
M
IN
G
&
RE
SE
T
CP
U
D
IS
PL
AY
SE
CT
IO
N
80
51
M
IC
RO
CO
N
TR
O
LL
ER
RS
-2
32
LE
VE
L
CO
N
VE
RT
ER
CU
ST
O
M
ER
IN
TE
RF
AC
E
D
AT
A
O
U
T
D
AT
A
IN
M
O
TO
R
H
EA
TE
R
M
O
TO
R
CO
N
TR
O
L
H
EA
TE
R
CO
N
TR
O
L
BU
FF
ER
S
TR
AN
SF
O
RM
ER
PO
W
ER
SU
PP
LY
+
5v
dc
TO
AL
L
CI
RC
U
IT
S
IC
BU
S
2
A
to
D
CO
N
VE
RT
ER
VO
LT
AG
E
RE
FE
RE
N
CE
4.
09
6v
dc
3
W
IR
E
BU
S
CA
LI
BR
AT
IO
N
TE
ST
PO
IN
T
RF
I
D
ET
EC
T
H
EA
TE
R
TH
ER
M
O
CO
U
PL
E
H
IG
H
TE
M
PE
RA
TU
RE
SH
U
T-
O
FF
AM
PL
IF
IE
R
CO
M
PA
RA
TO
R
BE
EP
ER
LE
D
IN
ST
RU
M
EN
T
AM
PL
IF
IE
R
O
U
TP
U
T
SE
CT
IO
N
IN
PU
T
SE
CT
IO
N
PR
EC
IS
IO
N
TH
ER
M
IS
TO
R
EXCLUSIVE FEATURES OF THE MODEL 2100 SIMULATOR
x
MICROPROCESSOR CONTROLLED: Mercury column is eliminated.
x
TEMPERATURE SENSOR: The Model 2100
incorporates a high precision temperature sensor.
x
Maintains a precise temperature of 34
o
C + .05
o
C or better.
x
Will not heat if temperature sensor is defective (shorted or open).
x
GUTH LABORATORY GLASS CONTAINER: Graduated 500ml + 5%.
x
NON-MAGNETIC METAL TOP HOUSING ASSEMBLY: Provides uniform headspace
heating.
x
POWER SWITCH: Safety On/Off - Double pole, double throw (DPDT).
x
ELECTRICALLY ISOLATED: Internal power transformer and optically isolated control
components prevent AC leakage.
x
FUSE: External fuse provides protection in the event of an electrical malfunction.
x
HIGH INTENSITY LED DISPLAY: Provides maximum visibility of temperature and heater
activity.
x
RELIABLE AGITATOR MOTOR.
x
AGITATOR PADDLE: Designed by Guth Laboratories, Inc. Offers maximum circulation
and uniformity of solution.
x
HEATER ELEMENT: Electronically protected from overheating when removed from
solution or when temperature sensor is defective.
x
RFI PROTECTED: The heating element and motor will turn off when the simulator is
subjected to a RF field of 10 volts/meter or greater.
x
INTERNAL DIAGNOSTICS: Simulator computer performs internal diagnostics.
x
MALFUNCTION INDICATION: Simulator provides an audible and visual indication if a
malfunction occurs.
x
POWER : 120 volts AC 60 Hz.
x
x
RS-232 COMMUNICATIONS: Provides the ability to monitor the temperature and status of
the simulator.
x
O
O
P
P
T
T
I
I
O
O
N
N
A
A
L
L
:
:
S
S
E
E
R
R
I
I
A
A
L
L
I
I
Z
Z
E
E
D
D
N
N
I
I
S
S
T
T
R
R
E
E
F
F
E
E
R
R
E
E
N
N
C
C
E
E
M
M
E
E
R
R
C
C
U
U
R
R
Y
Y
-
-
I
I
N
N
-
-
G
G
L
L
A
A
S
S
S
S
T
T
H
H
E
E
R
R
M
M
O
O
M
M
E
E
T
T
E
E
R
R
F
F
O
O
R
R
C
C
A
A
L
L
I
I
B
B
R
R
A
A
T
T
I
I
O
O
N
N
C
C
H
H
E
E
C
C
K
K
S
S
.
.
2
13
2