WARNING:

  

T

HE TERMINAL JUMPER MUST NEVER BE USED ON THE PRIMARY HEATER 

S

OLID 

S

TATE 

R

ELAY 

(SSR).  T

HIS WILL RESULT IN COMPLETE LOSS OF CONTROL AND CAUSE DAMAGE 

TO THE EQUIPMENT OR SERIOUS BODILY INJURY

 

c) 

Install the terminal jumper strip across terminals #1 and #2 on the Hose Heater 
SSR. 

 

d) 

Manual Hose Heat control requires the installation of a Hose Thermometer.  
Insert the thermometer through the sponge so that the stem follows the twist of 
the hoses and lies between the butyl inner hose and the outer sponge insulation.  
This gives the most accurate temperature indication.  The thermometer should 
be located on the end of the hose nearest the gun in a position where the 
operator can see it while spraying. 

 

e) 

Maintaining hose temperature 
now requires manual adjustment 
of the Hose Heat Power Set.  
Adjust the control clockwise to a 
maximum of 50 Amps for initial 
warm up and then adjust as 
required to maintain the hose 
temperature. 

f) 

Restore electrical power, switch 
ON the main switch and hose 
heat circuit breaker and monitor 
the thermometer for proper spray 
temperature. 

 

Figure 17.  Terminal Jumper Strip 

Installation 

 

WARNING: D

O NOT ALLOW HOSE TO OVERHEAT DURING MANUAL CONTROL OF THE HOSE 

HEAT SYSTEM

.  H

OSE TEMPERATURE

AS INDICATED BY A PROPERLY INSTALLED HOSE 

THERMOMETER

MUST NOT EXCEED 

170

°

 

F (76

°

 

C).

  

C

LOSELY MONITOR HOSE TEMPERATURE 

TO AVOID PERSONAL INJURY AND

/

OR DAMAGE TO PROPERTY

 

6.  TEMPERATURE SENSING UNIT (TSU)- Two conditions must be satisfied for 

proper operation: 

 

• 

The sensor must be functional. 

 

• 

The signal must travel uninterrupted from the sensor to the control unit. 

 

Unplug the TSU from its extension.  Without undoing any chemical connections, 
move the hose section with the TSU to the proportioning unit, plug the TSU directly 
into the TSU extension harness, restore electrical power and energize the hose heat 
circuit.  If control is not restored, change the TSU.  If control is restored, 
systematically check each section of the TSU wire harness out to the gun. 

 

7.  PRIMARY HEAT AND HOSE HEAT TEMPERATURE SETTINGS- The purpose 

of the hose heater is not to add heat but rather to maintain the temperature developed 
by the primary heater.  If indications are that the hose heater is not maintaining 
temperature during flow, check that the primary heater and hose are set for the same 
temperature or reduce the output. 

 

8.  LOW LINE VOLTAGE- The hose heat system operates at 220 Volts.  Low line 

voltage will significantly reduce power available and the heater will not perform to 

Содержание FF-2500

Страница 1: ...usmer Machinery Group Inc One Gusmer Drive Lakewood New Jersey USA 08701 8055 Toll Free 1 800 367 4767 USA Canada Phone 732 370 9000 Fax 732 905 8968 Copyright 2004 GUSMER CORPORATION http www gusmer...

Страница 2: ...ur local distributor NOTICE All statements information and data given herein are believed to be accurate and reliable but are presented without guarantee warranty or responsibility of any kind express...

Страница 3: ...CTIONS 14 HOSE HEAT POWER PACK 15 TEMPERATURE CONTROLLERS 16 HEATED HOSE INSTALLATION 17 AIR PURGE 20 OPERATION 21 DAILY START UP PROCEDURE 21 DAILY SHUT DOWN PROCEDURE 22 TROUBLESHOOTING 23 GENERAL I...

Страница 4: ...NGS 15 FIGURE 6 TEMPERATURE CONTROLLER 16 FIGURE 7 ISOLATION HOSES 17 FIGURE 8 HOSE CONNECTION STEP A 17 FIGURE 9 HOSE CONNECTION STEP B C 18 FIGURE 10 HOSE CONNECTION STEP D 18 FIGURE 11 HOSE CONNECT...

Страница 5: ...warranty provisions applied to product that are not manufactured by Gusmer will be solely in accordance with the warranty provided by the original manufacturer of the product GUSMER MAKES NO WARRANTY...

Страница 6: ...be required for specific use or application The following safety guidelines are generally applicable to the safe and efficient use of the equipment Acceptable Equipment Uses The equipment is designed...

Страница 7: ...ressure WARNING THIS EQUIPMENT HAS OR IS USED WITH EQUIPMENT THAT HAS HYDRAULIC AND CHEMICAL COMPONENTS CAPABLE OF PRODUCING UP TO 3500 PSI TO AVOID SERIOUS BODILY INJURY FROM INJECTION OF FLUID NEVER...

Страница 8: ...Model FF 2500 Proportioning Unit 8 25942 1 Issue 4 DESCRIPTION Figure 1 Model FF 2500 Proportioning Unit...

Страница 9: ...is automatic 6 PUMP SWITCH Controls operation of the air drive system OFF Air drive system is off NORMAL Must be in this position for the proportioning pumps to operate RETRACT Use this position for...

Страница 10: ...ide of the transformer 23 LOW VOLTAGE POWER PACK TRANSFORMER Provides selectable low voltage outputs for heating various chemical hose lengths 24 TSU EXTENSION ADAPTER Carries the electrical signal fr...

Страница 11: ...i maximum 27 bars AIR MOTOR 32 scfm 112 psi 12 liters sec 7 7 bars ELECTRICAL 38 amps 220 volts 50 60 Hertz single phase AC 29 amps 380 volts 50 60 Hertz three phase AC WEIGHT 140 pounds 63 kg DIMENSI...

Страница 12: ...Model FF 2500 Proportioning Unit 12 25942 1 Issue 4 INITIAL MACHINE SET UP Figure 2 Typical FF 2500 Installation...

Страница 13: ...URE THAT INCOMING POWER IS DISCONNECTED AND LOCKED OUT AT THE SOURCE IMPORTANT The main power source must be capable of meeting the electrical requirements specified on the nameplate of the proportion...

Страница 14: ...a generator will be powering the unit consult with your electrician about additional grounding measures that may be required Material Supply Connections Connect the material supply to the inlets of th...

Страница 15: ...line fuse B into the Power Lock hose heat connector on the end of the console wire A See Figure 4 Figure 4 Manual Transformer Connections 3 Using Figure 5 and the chart below connect the power lead C...

Страница 16: ...NOTE The temperature controller normally displays the set point When illuminated the red LED number 1 on the temperature controller indicates that the heater is in heating mode The LED goes out when t...

Страница 17: ...CKET TO PROTECT THE HOSES AND TSU EXTENSION HARNESS FROM DAMAGE 1 Connect the isolation hoses to their respective primary heater outlet fittings see Figure 7 IMPORTANT The heated hose assemblies are c...

Страница 18: ...the hoses are pressurized and found to be free of leaks Figure 10 Hose Connection Step d See Figure 11 for Steps e and f e Connect the TSU harness plugs together To ensure a secure electrical connect...

Страница 19: ...the ground point on the TSU d Connect the heated hose assemblies to the TSU taking care not to cross thread or over tighten the fittings thereby ensuring a leak proof chemical connection e Connect the...

Страница 20: ...3 8 Hold the coupling block with the A and R ports over separate containers and open both manual valves Figure 13 Pump Lubricant Cup 9 Set the pump switch to NORMAL If necessary gradually adjust both...

Страница 21: ...N the main switch The pilot light should be on 8 Uncoil the heated hose assemblies WARNING UNCOIL THE HOSES BEFORE SWITCHING ON THE HOSE HEAT CIRCUIT BREAKER TO PREVENT OVERHEATING THE HOSE ASSEMBLIES...

Страница 22: ...ired so that the proportioning pump pressure is equal on both the up and down strokes The proportioning unit is now ready for operation Daily Shut Down Procedure 1 Set the pump switch to RETRACT 2 Tri...

Страница 23: ...etent Certified Gusmer Technician Obtain information on these schools from SPI GUSMER maintains a competent staff of Technical Representatives and authorized Distributors who can resolve almost any pr...

Страница 24: ...for each problem to avoid unnecessary repairs Also determine that all circuit breakers switches and controls are properly set and wiring is correct before assuming there is a problem Turn off all swit...

Страница 25: ...ensure all electrical power is OFF e Reset the thermal limit switch by pushing in the red button on the switch f If the thermal limit switch does not feel as though it reset then disconnect one lead...

Страница 26: ...ing power at the source b Remove the heater cover box by removing the acorn nut and sliding the cover box away from the heater c Read the resistance across the four Heating Rods The resistance should...

Страница 27: ...or lights are out 4 5 6 Pump movement is erratic 7 Unequal pressure or speed on the upstroke verses the down stroke 8 SOLUTIONS 1 LEAKING BALL CHECK VALVE Determine which inlet and discharge ball valv...

Страница 28: ...erably lower than the isocyanate gauge see step 3 below 3 CAVITATION Cavitation is the formation of a partial vacuum or void created within the pump cylinder during the fill stroke It is actually a sh...

Страница 29: ...As this is a non lockout type of system the proportioning pumps will resume normal operation when the pressure bleeds off to approximately 200 psi However the cause of the over pressure condition sho...

Страница 30: ...the FF 2500 hose heater allows it to operate with up to 310 feet of hose Hose lengths greater than that reduce the ability of the hose heat to reach temperature See Initial Machine Set up In addition...

Страница 31: ...clockwise until the ammeter reads zero then turn OFF the hose heat circuit breaker and main switch and repeat Steps c through e until the fault is located 5 DIGITAL HOSE HEAT SOLID STATE RELAY SSR It...

Страница 32: ...lation WARNING DO NOT ALLOW HOSE TO OVERHEAT DURING MANUAL CONTROL OF THE HOSE HEAT SYSTEM HOSE TEMPERATURE AS INDICATED BY A PROPERLY INSTALLED HOSE THERMOMETER MUST NOT EXCEED 170 F 76 C CLOSELY MON...

Страница 33: ...ch primary heater and hose heater circuit breakers OFF change the sensor leads on terminal numbers 1 and 2 10 SENSOR TYPE MISMATCHED The preprogrammed controller operates with a type E Thermocouple on...

Страница 34: ...seep past the pump packing onto the pump shaft Maintain proper packing adjustment to minimize seepage Routinely inspect the shaft and wipe away any residue when the proportioner is turned off Disasse...

Страница 35: ...appropriate container open the corresponding manual valve of the side to be worked on and bleed chemical pressure to ZERO 2 Disconnect the transfer pump air supply and close the material inlet supply...

Страница 36: ...of isocyanate past the pump packing during operation However if the packing within the isocyanate pump is functioning properly pump lubricant replacement due to discoloration should not be more freque...

Страница 37: ...ber Field Title Description 1 Date 2 Name 3 IM Number 4 Issue Number 5 Date of Issue 6 Page Number 7 Discrepancy Instructions Complete the above fields of the form by following the instructions listed...

Страница 38: ...e 4 Issue Number Enter the Issue number of the Instruction Manual from the title page If there is no issue number enter NONE 5 Date of Issue Enter the date of Issue of the Instruction Manual from the...

Отзывы: