28
INFO
59)
Nein
......................... Setting for boilers without an EC filter.
Bj. 2016
................... Setting for boiler with EC filter and year of construction 2016 on the type plate.
ab Bj. 2017
.............. Setting for boilers with EC filter from year of construction 2017 on the type plate.
Ja
............................. Activation of the EC filter on new boilers.
60)
No
............................ Deactivates the outside sensor and gives the controller an outside temperature of 0°C.
Yes
.......................... Standard setting for weather-compensated heating systems.
61)
In the parameter, under OPT, the optimal amount of fuel to be inserted is displayed. In the case of deflagration during heating
operation, e.g. For example, try setting a smaller fuel table for troubleshooting. A larger fuel table can lead to incomplete combustion
and boiler malfunctions due to increased feed amounts.
62)
single
....................... A clock program with up to 3 switching times can be programmed daily for each heating circuit.
multible
................... Three weather-compensated clock programs (COLD, MILD and WARM) with up to 3 switching times can be
programmed daily for each heating circuit.
Attention
The change between the weather-dependent clock programs depends on the average temperature of the previous
day and may take place with a time delay until one day later.
63)
No
............................ Deactivates the photo sensor and thus the combustion monitoring.
Yes
.......................... Standard setting for pellet devices.
64)
Starts the automatic photo sensor calibration during the operating status Control.
65)
Input option for photo sensor correction values in the low load range (Pmin) and in the nominal load range (Pmax).
66)
No
............................ Deactivates the lambda probe.
Bosch
...................... Setting for older boilers with Bosch lambda probe.
NGK
......................... Setting for new boilers with NGK lambda probe.
67)
Permanent
.............. Setting for older boilers with Bosch lambda probe.
Auto
......................... Setting for new boilers with NGK lambda probe.
68)
Manual start of the automatic lambda sensor calibration.
Attention
This process can take a long time (approx. 30 minutes).
69)
The ideal measured value of the lambda probe is -10mV in the test program. Deviations up to a maximum of ± 6 mV are permissible
and may be entered as a correction value. If the deviation is greater, the lambda probe must be replaced.
70)
After calibrating the lambda probe in the lower measuring range to 0.0%, the probe can be calibrated in the upper measuring range
(nominal load range at approx. 10-12% CO2) by adjusting the lambda characteristic.
Example
The CO2 value displayed on the boiler at nominal load differs by e.g. 2% in the control measurement using a
calibrated emission measuring device (display on the boiler 10%, on the measuring device 12%). The deviation of
2% can be entered in the parameter as a correction value and thus causes the probe to be calibrated in the upper
measuring range.
71)
Terminal
.................. Data query via VISU.
DAQ
......................... Data retrieval via online recorder (can only be used at the factory).
GSM-Modul
............. Info and control via GSM module.
72)
Takt
......................... Control for naturally aspirated engines with pulsed speed control.
0-10V
....................... Control for naturally aspirated motors with 0-10V speed control.
73)
No
............................ Setting for standard naturally aspirated engines.
Yes
.......................... Setting for EC naturally aspirated motors.
74)
D140
........................ Setting for Biostar 12 and 15.
D150
........................ Setting for Biostar 23.
75)
Influences the display of the boiler release menu in the boiler program selection.
Normal
..................... Possible selection = AUTO or OFF
Service
.................... Possible selection = AUTO, OFF or PERMANENT
76)
3.0
............................ Menu structure without system image on the house level.
3.1
............................ Menu structure with system image on the house level.
77)
Anti-blocking system for all pumps, mixers and valves (every Monday at 12 noon).
78)
Forced switch-on for all heating circuits and hot water pumps until the boiler or buffer tank falls below 85°C.
79)
Pump HP0 on until the boiler temperature falls below 65°C.
80)
If the outside temperature falls below the temperature set in the HKP Frost TA parameter, the frost protection function becomes active.
All heating circuit pumps switch on and regulate to the set flow temperature set in the HKP Frost TV parameter.
Attention
The frost protection function can fail due to a fault in the boiler! → Provide electric heating element!
81)
TEST FUNCTION
The boiler temperature is increased until the STB interrupts the function.