Guntamatic BIOSTAR BOX Скачать руководство пользователя страница 1

 

 

 

Pelletfiring 

englisch

 

BIOSTAR

   Complete 

Operating instructions

 

 

EN-B30-003-V21-0322

 

 

Содержание BIOSTAR BOX

Страница 1: ...Pelletfiring englisch BIOSTAR Complete Operating instructions EN B30 003 V21 0322...

Страница 2: ...ved GUNTAMATIC Heiztechnik GmbH Bruck 7 A 4722 PEUERBACH Tel 0043 0 7276 2441 0 Fax 0043 0 7276 3031 Email office guntamatic com It is important that you pay particular attention to the safety issues...

Страница 3: ...2 Customer level 17 6 2 1 Customer menu 18 6 2 2 Heating circuit 19 6 2 3 Hot water 20 6 2 4 HP0 20 6 2 5 Pipeline 21 6 2 6 APP 21 6 2 7 Servicelevel 22 6 2 7 1 Resetdata 22 6 2 7 2 Beginning Service...

Страница 4: ...uel 35 8 3 Fill storeroom 36 8 4 Emptying the ash 37 9 Cleaning care 38 9 1 Interim cleaning 39 9 2 General cleaning 40 10 Error Fault messages 41 11 Fault clearance 42 12 Replacing fuses 43 13 System...

Страница 5: ...ed specialist Above all follow the safety instructions in Chapter 2 Short description The BIOSTAR furnace is a modern boiler The discharge takes place from a storage room by means of a suction system...

Страница 6: ...aining it correctly Only start up the heating system when it is in perfectly safe working order 2 1 INTENDED USE BS 01 The boiler is designed for heating central heating water and for use as a central...

Страница 7: ...imes and may only switched off when the system is not in operation Mains plug Risk of fatal injury from electric shock The mains power supply is brought to the boiler via the plug marked Mains That pl...

Страница 8: ...f injury from rotating parts The fan must only be removed when it is disconnected from the power supply unplugged Gaskets Risk of gas poisoning It is possible that flue gas could escape if gaskets are...

Страница 9: ...ogenic substances can form gases during storage Entering the storage room is therefore only permitted when the storage room is empty max 1 5 remaining content and after at least 2 hours of good ventil...

Страница 10: ...exceeds 100 C the boiler room must be vacated immediately Under no circumstances may boiler doors or maintenance openings on the boiler be opened Plant remote access Attention risk of injury If remot...

Страница 11: ...us electric voltage Warning of rotating components Warning of hot surfaces Warning of deflagration grounding Observe operating or installation instructions Separate electric system from the mains Pull...

Страница 12: ...ic heat exchanger cleaning 10 Grate cleaner motor 11 Ignition fan 12 Ceramic insulation 13 Overall insulation 14 Helix baffels 15 Tube type heat exchanger 16 Flue draught fan 17 Flue gas sensor 18 Lam...

Страница 13: ...the heating circulation pumps continue to run The system remains switched off even if the boiler temperature drops back below 90 C The system must not be started up again until any faults have been r...

Страница 14: ...rying out repairs or servicing work STB 2 Excessive temperature trips the safety temperature limiter STB located under the cap 2 appliance operation is suspended if the STL has tripped identify and el...

Страница 15: ...Status OFF Heating circuit INFO Boiler NORMAL DHW INFO filter DHW DHW extra INFO Controller HEAT Buffer storage INFO Buffer REDUCE Pipeline REDUCE TO Detail display BOOST DHW APP MANUAL OPERATE Date...

Страница 16: ...ror messages Temperatures Scold and operational states Buffer and Heating circles could be requested Programmes for boilers and heating circulations could be chosen the boilers release could be broken...

Страница 17: ...BS 02 Boiler s clearance on Attitude OFF the boiler didn t start Program OUT Heatingrun turned off Program NORMAL Heizung und WW Bereitung eingeschaltet nach Uhrenprogramm Program WARM WATER heating...

Страница 18: ...king times Filter ash emptied Select the menu after emptying the filter ash and confirm with YES and OK Ash warning filter Hours until the next ash warning on the display the filter ash must be emptie...

Страница 19: ...ld Only heating mode according to the MILD timer program Warm Only heating according to the WARM timer program 6 Control to the DAY SET TEMPERATURE is only possible during the heating phase of the hea...

Страница 20: ...program buffer Affects the boiler release Buffer target Affects the target buffer temperature 17 Buffer min Affects the minimum buffer temperature back to the costumerlevel look at Chapter 6 2 INFO Th...

Страница 21: ...ffer sensor T3 is not reached the buffer is automatically loaded again according to the set loading program FULL or PARTIAL to the set buffer target temperature Attention The HKR 0 2 release must be O...

Страница 22: ...Long distance line parameters look Chapter 6 2 7 6 24 Return mixer parameters look Chapter 6 2 7 7 Plant settings look Chapter 6 2 7 8 Parameter menu Entry and changes only permitted in consultation...

Страница 23: ...circuit control wall unit set MK 261 as controller 1 or 2 27 0 5 0 7 Basic setting for underfloor heating 1 2 1 4 Basic setting for radiators 28 No Setting for heating circuits without room unit room...

Страница 24: ...temperatures cannot be guaranteed 100 due to various safety circuits and special boiler functions significant excess temperatures can occur in exceptional cases If this is problematic in terms of str...

Страница 25: ...C factory setting for the boiler to start again Example highest requirement temperature 50 C Boiler start when temperature falls below 44 C at top buffer sensor 43 The switch off condition for the lo...

Страница 26: ...using the factory setting at 61 C at the top of the buffer 61 C Buffer TOP temperature Buffer target temperature 55 C plus Po charge OFF part 6 C 52 Specification of the source from which the energy...

Страница 27: ...rameters Selection OFF SD data Selection CID data Selection Network VISU over network Selection Error messages Selection do not disable First filling Selection 72 Induced draft Selection TAKT 73 EC de...

Страница 28: ...ns up to a maximum of 6 mV are permissible and may be entered as a correction value If the deviation is greater the lambda probe must be replaced 70 After calibrating the lambda probe in the lower mea...

Страница 29: ...press the programmeselection Programme OUT Heating and Warmwater turned off Programme NORMAL Heating and Warmwater on Programme WARMWATER just Warmwater on some INFO s more for Programme selection lo...

Страница 30: ...ed With the function Weekprogramming all days in a week could be programmed at the same time 03 1 press COSTUMER LEVEL 2 press on the heating circulation button 3 press on the watchtime progtamme Prog...

Страница 31: ...apted Through a higher heating curve you might reach a higher room temperature Change the heating curve just daily and maximum in a tenth area 03 1 press COSTUMER LEVEL 2 press to the heatingbend butt...

Страница 32: ...Through changing the targettemperature the warmwatertemperature could be adapted 03 1 press COSTUMER LEVEL 2 press on the warmwaterbutton 3 press on the targettemperature button CHANGE with or SAVE wi...

Страница 33: ...nobs bringst he the oportunity to change the roomtemperature In the plus area of the menu the roomtemperature could be lifted up to 3 C In the control range the minus temperature could be depressed up...

Страница 34: ...control and safety systems to ensure they are safe and functional We recommend that you take out a maintenance contract so that the system operates safely and economically 8 1 CONTROLING OF THE HEATI...

Страница 35: ...id smooth surface minimal small particle minimal ash decay high smelting point only use recommended fuels tested and recommended with low fines and dust content made from low potassium low nitrogen an...

Страница 36: ...isn t able to run the store room could be emergency refilled Before you try to eliminate the error follow the description as you can see in the chapter Rectifying faults or Replacing fuse approach Put...

Страница 37: ...ruction to Programme out and let it cool down minimum a half an hour Then you have to extract and clean the ashtank Attention The Ashton could be hot After checking that they are in good condition rei...

Страница 38: ...cleaning for which the precise procedure is described in the section Complete cleaning may be required twice a year but should be carried out at least once a year Depending on efficiency and on ash p...

Страница 39: ...door 1 take of the ash box 2 and empty it Risk of burns from hot parts Fire danger thoruh rest ember 3 Peel the bouncing plate with the burningchamber 3 with a poker stick Insert the poker stick the l...

Страница 40: ...ht hub if necaserry built it out and clean it with an soft brush Don t clean the Lambdasond with highairpressure 10 Take off the foto cell 13 and clean it with an soft cloth Open the revision lid 14 a...

Страница 41: ...groom will be not go under spiralsrunningtime LZ G1 min Filler levels doesn t react F08 None Filler levels dusty or faulty F12 Fault No response from Hall effect sensor G1 within time t safe Drive mot...

Страница 42: ...s on the part of heating system components Re adjust flue draught regulator Stagger heating system component demand over time Burning fault Lambdaprobe dirty Lambdaprobe loosley Lambdaprobe malfunctio...

Страница 43: ...wn for at least 10 minutes 2 Switch the Power switch to 0 and unplug the mains plug on the back of the boiler to fully disconnect it from the power supply 3 Unfasten the controller cover and remove it...

Страница 44: ...Heating circuit 0 Heating circuit 1 Heating circuit 2 Hot water 0 15 TO DISPOSE BS 01 Observe disposal regulations Observe the locally applicable regulations for the disposal of waste and machine part...

Страница 45: ...45 NOTES...

Страница 46: ...cation of parts of the system or the entire system that has not been agreed with us this declaration automatically loses its validity Guidelines 2006 42 EG Machinery Directive 2006 95 EG Electrical eq...

Страница 47: ...47 NOTES...

Страница 48: ...48 GUNTAMATIC Heiztechnik GmbH A 4722 Peuerbach Bruck 7 Tel 0043 0 7276 2441 0 Fax 0043 0 7276 3031 Email office guntamatic com www guntamatic com Misprints and technichal Changes reserved...

Отзывы: