Dokument-No.:2013366
Version a
page
8
Creation date: 28.11.2007
3.3.
Change of time parameters at the control unit “Easy”
The control is switched on and the word “run” will appear on the bottom at the right hand side of
the display.
With the ok key you enter the main menu.
Here you can confirm the menu option parameter selection (parameter flashes) by using the arrow
keys up/down and the ok key. Now you are in the submenu parameter, where all alterable times
are shown.
You can select a time parameter by using the arrow key up/down.
After the parameter (e.g. T1) is selected, confirm this with the ok key. The chosen time with its
values will appear on the display (screen). By using the arrow keys you can select the current
value which should be changed and confirm with the ok key.
Now you can move by using the arrow keys left/right in the line back and forth and increase or
decrease the value with the arrow keys up/down.
Changes of values must be confirmed with the ok key.
With the “Esc”-key you will jump back to the previous step.
After you finished your changes, repeatedly press the Esc key, until the word “run” appears again
at the bottom on the right hand side of the display.
Parameter
Description
Factory setting
T1
running time
15 sec
T2
reversal time
2 sec
T3
advance warning time raising
1 sec
T4
auto-closing after passage
2 sec
T5
follow-up time lower
0 sec
T6
follow-up time raise
0 sec
T9
advance warning time lower
1 sec
T10
auto-closing after no passage
20 sec