41
Press ON/OFF on the display, the unit should start after a
3.
few seconds.
After a few minutes, check that the exhaust air is colder
4.
than the outdoor air temperature (5-10 ºC).
Stop the pool’s circulation pump and make sure that the
5.
pool heat pump stops automatically.
Let the system run around the clock until the required
6.
temperature is reached. The pool heat pump will know
when the temperature has been reached, but will not
switch off until the required temperature has been
exceeded by 1º. The pool heat pump will then start again
when the temperature in the pool drops by 1º below the
required temperature.
Flow switch:
The pool heat pump is equipped with a flow
switch that prevents starting in the event of insufficient water
flow.
Time delay:
The compressor will start after a delay of
approximately 1 minute to prevent repeated restarts and
compressor wear. Even a brief power failure activates the
start delay of 1 minute.
Installation
40