CLEANING & MAINTENANCE

14

Cleaning The Magnet Jet (Step by Step)

1. Pull Magnet Jet off from the pedicure bowl
2. Turn the Top Plate of the Magnet Jet counter-clockwise
3. Separate the three components of the Magnet Jet: Top Plate, Magnet, Back Plate
4. Wash each component of the Magnet Jet in a recommended or high quality solution or cleaning agent
5. Reassemble the Magnet Jet using the following directions:
    - Notice that on the Back Plate there is a small hole (1/16’’ of an inch), this small hole indicates the bottom of the
      Back Plate
    - Put the Magnet, with the three circles facing upwards, in the center of the plate on top of the Magnet and the
      Back Plate
      so that the tab is slightly left from the “top”
    - Turn the Top Plate clockwise until you hear a “click-sound”
** Note: there are 3 pegs on the back of the Back Plate, the pegs which has small holes (1/18’’ of an inch) should
    be aligned with the Top Plates tab after the “click-sound”
6. Remount the Magnet Jet onto the pedicure bowl by aligning the pegs so that the tab is at the top of the Magnet Jet

Top Plate

Magnet

Back Plate Top

Back Plate Bottom

Three Magnet Jet Components

Warning

!

 

- Do not run 

MAX without water. This will 

void

 your warranty

- Do not place two wet ends in the same bowl when cleaning
  the jet’s strong magnets could cause 

injury 

(pins your fingers)

- Do not attach two wet ends to each other. Doing so will cause
  breakage to wet ends and will 

void

 the warranty

®

Cleanjet

Содержание CHI SPA

Страница 1: ... without notice 2011 All rights reserved PLEASE SAVE THIS MANUAL FOR FUTURE REFERENCE OWNER MANUAL Cleanjet Gulfstream Inc Gulfstream Inc TM Mariposa are trademarks of TM FOOT SPA Mariposa Acrylic Tub Glass Bowl Patent Pending Patent D610697 D600950 ...

Страница 2: ... and Precautions INSTALLATIONS Attaching Seat Jet Cover Assembly Plumbing Connections 1 2 Identifying Parts 3 5 8 9 10 Warranty Service 15 7 Owner Manual Operations and Use Cleaning Maintenance 11 12 13 14 Foot spa Clearance 6 ...

Страница 3: ...cause severe damage to the unit as well as possible serious injury to the person BASIC PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING 1 Read and follow all instructions 2 DANGER To reduce the risk of injury do not permit children to use this unit unless they are supervised at all times 3 Use this unit only for its intended use as described in this manual Do not use attachments that ...

Страница 4: ...ir a damaged cord OPERATION AND USE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS 1 IMPORTANT At the end of the day ALWAYS turn the main power OFF 2 DANGER To reduce the risk of injury do not permit children to use this unit unless they are closely supervised at all times 3 CAUTION This unit should not be used by persons with open wounds cuts or sores on their feet or legs or by persons with poor ...

Страница 5: ...2 Seat Cushion 3 Wings 4 Back Cushion 5 Armrest 6 Manual Seat Adjustment Handle 7 Adjustable Footrest 8 Adjustable Footrest Lock 9 Front Control Panel 10 Jet 11 Drain 12 Drain Control 13 Water Control 14 Jet Control 15 Hand Spray 9 Control Panel Front Back Glass Bowl Model ...

Страница 6: ...ushion 3 DVD Player Optional 4 Wings 5 Back Cushion 6 Arm Rest 7 Manual Seat Adjustment Handle 8 Adjustable Footrest 9 Front Control Panel 10 Drain 11 Jet 12 Drain Control 13 Water Control 14 Hand Spray 15 Jet Control Acrylic Tub 3 Control Panel 7 8 9 11 10 Acrylic Tub Model ...

Страница 7: ...5 IDENTIFY YOUR FOOT SPA Manually Sliding Forward or Backward SEAT OPERATION SPA DIMENSION 49 29 32 46 5 15 5 Adjustment Handle 22 ...

Страница 8: ...6 FOOT SPA CLEARANCE Wall 16 60 60 16 16 28 Foot spa 1 Center Center Foot spa 2 TYPICAL FOOT SPAS Clearance WALL CLEARANCE Mariposa 1 35 Mariposa 2 36 Distance from center drain to the back of the spa ...

Страница 9: ...STALLATIONS Align the seat with the pre drilled holes on the base then tightly secure with the nuts and bolts provided Attach Wings Attaching The Seat to The Base Using the same steps for Acrylic Tub Model ...

Страница 10: ...gs To remove the jet unit components Turn the top plate counter clockwise in the arrow direction Jet Unit Components To install the jet unit Assemble all jet unit components in order as before removal snap the jet unit onto the anchor pegs located on tub bowl wall securely Note All jet unit components must be assembled in sequence of order to avoid malfunction Screws Please call manufacturer for r...

Страница 11: ...the UPC codes do not allow double P Traps in the system 3 Hot and cold water supply connections are located at the rear of the unit fittings Please be advised that the hot and cold water supply lines are not fitted with optional back flow Preventers unless ordered at initial sale 4 Have a qualified licensed electrician to install the wiring according to local codes The Cleanjets are 1 18 HP 120V A...

Страница 12: ...ump Installation Existing Hot Cold Water Supply Backwater valve sold separately GFI Outlet Required Existing Hot Cold Water Supply Backwater valve sold separately Floor Wall 16 24 Hot Cold Hoses Typical Gravity Sink Direct Drain Installation Gravity Sink 2 3 drain pipe to sewer line Backwater Valve sold separately P Trap not installed in the floor drain installation ...

Страница 13: ...charge pump Open the drain plug by turning the control knob as shown above Press discharge pump timer button Pump will run for approx 2 min Average time for drain 1 minute Control Panel Glass Bowl Model OPERATIONS USE 11 BASIC PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING 1 Read and follow all instructions 2 DANGER To reduce the risk of injury do not permit children to use this uni...

Страница 14: ...g Knocking Width Lower Adjustment Incline Seat Forward Seat Backward Recline Intensity Air On Off Back Waist Kneading Upper Adjustment Speed Knocking Timing Upper Body Knead Flap Knead Flap Neck Shoulder Press Knock Back Waist Back Stretching Speed Width Seat On Off Intensity Mode Seat Forward Seat Backward Seat Incline Seat Recline Power LCD TT960 Manual ...

Страница 15: ...lpool for 15 minutes drain and then wipe dry with clean soft cloth NOTE Cleaning or sanitizing is NOT disinfecting According to the Centers for Disease Control and Prevention CDC and the US Environmental Protection Agency EPA disinfecting occurs only when there is a reduction of pathogenic microbes at 99 999 Sanitizing is only a reduction of 99 9 Cleaning of whirlpool pedicure spas requires surfac...

Страница 16: ...on top of the Magnet and the Back Plate so that the tab is slightly left from the top Turn the Top Plate clockwise until you hear a click sound Note there are 3 pegs on the back of the Back Plate the pegs which has small holes 1 18 of an inch should be aligned with the Top Plates tab after the click sound 6 Remount the Magnet Jet onto the pedicure bowl by aligning the pegs so that the tab is at th...

Страница 17: ...of plastic surfaces due to exposure and or the use of harmful cleaning agents or chemicals 3 Staining fading or discoloration caused by improper or poor water additives not related to the maintenance of proper water are not covered by this warranty 4 Staining fading or discoloration of the seat armrests or footrests 5 Freight damage misuse neglect accident natural disaster and abuse 6 Unauthorized...

Страница 18: ...ns are subject to change without notice 2011 All rights reserved Manufacturer of Acrylic Bath Whirlpool Pedicure Foot Spas Gulfstream Inc Cambridge Ontario Canada N1R 5X5 Tel 519 622 0950 Fax 519 622 6926 www gulfstreaminc com ...

Отзывы: