29
CODE
DESCRIPTION
CORRECTIVE ACTION
SP Ot
Internal
overheat
•
Open the access panel to the spa pack
(below the control panel) and allow
two hours to cool down
•
Reset GFCI breaker
Low-Level Settings
The spa pack – located inside the spa below the
topside control panel – has a service panel used to
set your spa’s low-level programming options. During
troubleshooting, you may need to check or reset these settings.
Note
: If your spa comes with a stereo, unplug the orange Di plug
on the top right corner of the pack during any of these steps.
Resetting the Spa Pack –
To reset the spa pack, press the Select
button twice.
Breaker current setting
– To adjust the breaker current setting (Br),
press the Select button and then press the Change button. The
normal current settings are:
For 240V 60Hz spas:
Br = 40
For 240V 50Hz 1
φ
spas:
Br = 1P
For 240V 50Hz 2
φ
spas:
Br = 2P
For 240V 50Hz 3
φ
spas:
Br = 3P
Low-level setting
– To reset
the low-level setting (LL), press
and hold down the Select
button for 5 seconds. Use the
Change button to set LL=01
(even if the present value is
01). Press Select to save.
Note:
Wait 10 minutes and
plug the orange Di plug back
in.
Heater 1
Pump 1
Pump 2
Blower
Ozonator
Stereo
Heater 2
Topside
Light
Select
Change
Содержание LX 11000
Страница 13: ...11 European 1x32A Wiring Diagram Jumper L1 L2 L3 ...
Страница 14: ...12 European 2x16A Wiring Diagram Jumper L2 L3 ...
Страница 15: ...13 European 3x16A Wiring Diagram No Jumper ...
Страница 48: ...46 Notes ...
Страница 49: ...47 Notes ...
Страница 50: ...48 Notes ...
Страница 52: ...11620 54th Street North Clearwater FL 33760 727 573 9888 www GulfCoastSpas com ...