User Manual
65
•
To save the change, choose button OK or press the joystick directly; to cancel the change,
choose button Cancel or press button C directly. Then the dialog box will be closed and
the original image status will be resumed.
•
Button OK and button Cancel can be selected by the touch pen directly or by pressing
button S first and then pressing the joystick.
•
IsoColor:
To choose a certain color for isotherm, black, white or green.
•
SpotNum:
To set the number of spots for spot analysis, up to 10 spots are available.
•
AreaNum:
To set the number of areas for area analysis, up to 10 areas can be set.
•
AreaFunc:
To set the temperature type of areas in area analysis, maximum, minimum or
average.
•
AudioAlarm:
To activate or inactivate the audio alarm for live thermal images.
•
AlarmTemp:
To set the scene temperature threshold above which the audio alarm will
sound.