Page 13 of 13 

 

Failure 

Possible Cause 

Corrective Action 

The run time for 
appliance is less 
than expected. 
 

The internal battery is 

not fully charged. 

Recharge the power pack by using 
the AC charger until the unit is fully 
charged. 

The alarm sounds  and reverse 
connection indicator is on. 

The jump start cables are 
connected incorrectly. 

Connect the jump start cables the 
correct way. 

The AC appliance does not operate, 
alarm is sounding and 

“Over load” on 

screen. 

The overload protection 
feature trips, as the AC 
appliance is rated more 
than 200 W. 

Use AC appliance with a power 
rating of less than 200 W. 

The AC appliance does not operate, 
alarm is sounding. 

“Low input” on 

screen. 

The battery has 
discharged to less 
than 11 V. 

Recharge the battery. 

The AC appliance does not operate, 
alarm is sounding. 

“Overheat” on 

screen. 

The power pack is 
overheated due to 
poor ventilation or 
excessively warm 
environmental conditions. 

Allow the power pack to cool for 
15 minutes or 
more. Clear blocked ventilation 
opening or 
remove objects covering the 
power pack, then 
restart the power pack.   

 

Содержание 699784

Страница 1: ...confident competitive edge that strikes the perfect balance between performance and value 200W 800A Power Pack 699784 For assistance with your Guide Gear product please contact the Sportsman s Guide customer service at 1 800 888 5222 7am 7pm CST Mon Fri or e mail us at custserv sportsmansguide com www SportsmansGuide com ...

Страница 2: ...lt LED Light Emitting Diode PSI Pounds per Square Inch Specifications 12V DC Power Section Boost Ampere 800A instantaneous cranking amps Battery 20Ah 12V Sealed lead acid battery Jump Start Cables size length 6AWG 2Ft AC charging adapter 15V 400mA 12V DC power socket 20A max fuse protected 5V USB output 3 1A shared for two USB ports Air compressor 100 PSI lb in2 115V AC Power Section Output Power ...

Страница 3: ...nown to the State of California to cause cancer birth defects or other reproductive harm Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Some examples of these chemicals are lead from lead based paints crystalline silica from bricks and cement a...

Страница 4: ...ooting and balance at all times Ensure the power switch is off prior to plugging in the tool Remove keys or wrenches before connecting the tool to an air supply power supply or turning on the tool A wrench or key that is left attached to a rotating part of the tool may cause personal injury Secure the work with clamps or a vise instead of your hand when practical This safety precaution allows for ...

Страница 5: ...isk of starting the tool accidentally Store the power pack when it is not in use Store it in a dry secure place out of the reach of children Inspect the tool for good working condition prior to storage and before re use Use only accessories that are recommended by the manufacturer for use with your power pack Accessories that may be suitable for one product may create a risk of injury when used wi...

Страница 6: ...rity connection damages the unit and or creates a spark or explosion This may lead to accumulations of hydrogen causing exposure to fire and explosion hazards This condition is typically found in marine appliances or portable generators with DC output Do not connect the power pack to any AC appliance with neutral conductor connected to ground as doing so may damage the power pack Do not expose the...

Страница 7: ...r objects to metal causing a severe burn 7 Someone should be within range of your voice or close enough to come to your aid when you work near batteries 8 Have plenty of fresh water soap and a supply of baking soda on hand in the area of the batteries in case of contact with battery acid Baking soda neutralizes lead acid battery electrolyte 9 The product is supplied with a rechargeable sealed lead...

Страница 8: ...he DC ON OFF switch button to activate the DC sockets you can see indication on LCD screen and battery voltage and status Make sure the battery is fully charged before use 2 Open the DC outlet plastic cover 3 Plug the power cord of DC appliance into the DC socket 4 Turn ON the DC appliance 5 Press the DC ON OFF switch button to turn off DC power after each use 6 Recharge the power pack immediately...

Страница 9: ...age the transmission in park mode for an automatic transmission vehicle or engage the transmission in neutral for a manual transmission vehicle 6 Place the booster pack on a flat stable surface close to the battery of the vehicle 7 Connect the negative black clamp from the power pack to the chassis of the vehicle 8 Connect the positive red clamp from the power pack to the positive terminal of the ...

Страница 10: ... reversed polarity connection positive to negative may cause a spark and damage the equipment If the cable clamps are connected in reverse the reverse polarity LED indicator glows red and the audible alarm will sound If the glow of the correct connection indicator is green without the sound alarm the connections are proper Ensure that the power pack and the cables are away from the belts fans or a...

Страница 11: ...compressor fill hose back in the storage 10 Reinstall the valve cap back onto the tire valve stem 11 Recharge the unit after each use Recharging the Battery WARNING Always ensure that internal battery is fully charged Do not overcharge the battery Leaving a battery in a discharged state or without recharging every 90 days may result in permanent damage to the battery and poor boosting performance ...

Страница 12: ...e durability and efficiency of the battery Troubleshooting Use the table below to troubleshoot problems before contacting service personnel or your local dealer If the problem continues after troubleshooting call your local dealer for assistance Failure Possible Cause Corrective Action The power pack does not jump start vehicle That battery in the jump starter is not fully charged Fully charge the...

Страница 13: ...g and Over load on screen The overload protection feature trips as the AC appliance is rated more than 200 W Use AC appliance with a power rating of less than 200 W The AC appliance does not operate alarm is sounding Low input on screen The battery has discharged to less than 11 V Recharge the battery The AC appliance does not operate alarm is sounding Overheat on screen The power pack is overheat...

Отзывы: