Vessel Parameters (continued)
RadaScan
Sensor
Vessel Centre-line
Connection
Panel
Operating
Area
Sensor Facing Aft
Connection panel facing forward,
Sensor parallel with vessel centre-line.
Bearing Offset =
0°
Sensor Facing Forward
Connection panel facing aft,
Sensor parallel with vessel centre-line.
Bearing Offset =
180°
Sensor Facing Port
Connection panel facing starboard,
Sensor perpendicular to vessel
centre-line.
Bearing Offset =
90°
Sensor Facing Starboard
Connection panel facing port,
Sensor perpendicular to vessel centre-line.
Bearing Offset =
−90°
180°
−90°
90°
0°
Key
Bearing Offset
Enter the correct Bearing Offset value on the Vessel Parameters pane (see
•
If the sensor is facing directly
Aft
,
enter a
0°
bearing offset.
•
If the sensor is facing directly
Forward
,
enter a
180°
bearing offset.
•
If the sensor is pointing to
Port
,
enter a
Positive
bearing offset, e.g. 90°
•
If the sensor is pointing to
Starboard
,
enter a
Negative
bearing offset, e.g. −90°.
46