Doc No 93-0491-4
UNCONTROLLED COPY ONCE PRINTED
PAGE 10 OF 21
Open the IPA gain and noise configuration spreadsheet and enter the noise source signal values and it will
work out the noise figure and gain for you. Enter this into section 4.4 of the build record.
Repeat again for remote station F1.
Power down the unit and swap the noise source over to the DIF side, reconnecting the SUM into the
system.
Power up the Artemis unit and put into operating mode. Repeat the test that was carried out on the SUM
channel and enter the results into section 4.4 of the build record.
Power down the Artemis and remove the noise source from the system.
6.
AGC Amplifier
Power down the Artemis and remove the AUP, then remove the two jumper links on the AUP and then fit
back into the Artemis.
Connect up the Artemis as shown below:
HP 8116A
Pulse/Function
Generator
Spectrum
Analyser
Attenuator
20
SUM Channel
ICB/AUP
Input Cable
DIF Channel
ICB/AUP
Input Cable
Jumper