Immediately switch the generator off under conditions as follows:
- unsteady or uneven engine run
- electrical output decline
- connected appliance overheating
- excessive generator vibrations
- sparkling
- smoke or fire
•
Make sure that there is enough fuel before connecting the generator to the appliance
•
Never refuel while the unit is running. Before refuelling, let the unit cool down for 54 minutes as a minimum after any
use.
•
Never touch the unit hot parts.
•
Do not store fuel near the unit.
•
The silencer and the air filter work as flame trap. Make sure that the parts are installed correctly and in perfect
condition.
Operation
Use of Generator „Turning On“
Fig. 6
•
Open the petrol cock by turning (ON).
•
Put the choke in the starting position (see sign on the
air filter).
•
Pull the starting cable slowly until resistance is felt,
then make a strong pull to start the engine.
•
When the engine gets heated up, push the choke in
the initial position and wait for the indicator to light up.
•
Connect the appliance cable
•
If the output is overloaded, the overloading fuse will trip. The
indicator lights on.
•
The generator will switch off automatically at short circuit.
Generator Turning Off
Fig. 7
•
Make sure that NO appliance is connected.
•
Put the on/off switch in OFF position.
•
Turn the fuel cock to OFF.