Security Advise

1

Security Advise

The device must be installed only by qualified personnel according to the following installation and operating instructions. 
The manufacturer does not accept responsibility in case of improper use of the device and particularly any use of equipment
that may cause personal injury or material damage.
The device contains no user-maintenable parts. All maintenance has to be performed by factorytrained service personnel.
Check if the power cord, the plug and the socket are in proper condition.
The device can be connected only to 230V AC (50 or 60 Hz) sockets.
Always connect the device to properly grounded power sockets.
The device is intended for indoor use only. Do NOT install them in an area where excessive moisture or heat is present.
Because of safety and approval issues it is not allowed to modify the device without our permission.
Please note the safety advises and manuals of connected devices, too.
The device is NOT a toy. It has to be used or stored out or range of children.
Packaging material is NOT a toy. Plastics has to be stored out of range of children. Please recycle the packaging materials.
In case of further questions, about installation, operation or usage of the device, which are not clear after reading the manual,
please do not hesitate to ask our support team.

2

Description

The Remote Power Switch Expert Power Control NET 8x 8210 / 8211 allows the switching of electrical devices via a TCP/IP
network and a serial interface.

For installation just connect the power and network cables to Expert Power Control NET 8x 8210 / 8211.

After the device has received an IP address every client in the same network is able to switch the eight Power Ports (max. 10
A)  via  webinterface.  Expert  Power  Control  NET  8x  8210  /  8211  offers  also  features  like  SNMP  and  Syslog.  Additional
Expert Power Control NET 8x 8210 / 8211 can be controlled via a serial connection.
A temperature sensor and a hybrid sensor (temperature and humidity) can be connected to Expert Power Control NET 8x
8210 / 8211
.

A watchdog function for each power port is implemented.

The display on the front is able to show the IP address, the recent total load, the peak current (timeframe adjustable) and the
measurements of the sensors.

Furthermore the access to the device can be restricted by IP access control lists and a HTTP password. 

Содержание Expert Power Control NET 8x 8210

Страница 1: ...2010 Gude Analog und Digitalsysteme GmbH Expert Power Control NET 8x 8210 8211...

Страница 2: ...Expert Power Control NET 8x 8210 8211 2010 Gude Analog und Digitalsysteme GmbH 23 08 2010...

Страница 3: ...on via webinterface 4 3 1 Configuration Power Ports 10 4 3 2 Configuration IP address 12 4 3 3 Configuration IP ACL 13 4 3 4 Configuration HTTP 13 4 3 5 Configuration Messages 14 4 3 6 Configuration S...

Страница 4: ...4 Table of content Expert Power Control NET 8x 8210 8211 2010 Gude Analog und Digitalsysteme GmbH 21 6 4 Fabrique settings Chapter 7 Support 22 Chapter 8 Declarations of conformity 23...

Страница 5: ...toy Plastics has to be stored out of range of children Please recycle the packaging materials In case of further questions about installation operation or usage of the device which are not clear afte...

Страница 6: ...wer Control NET 8x 8210 8211 Description 3 Hardware 3 1 Content of delivery Included in delivery are Expert Power Control NET 8x 8210 8211 Power supply cable IEC CD ROM including Software and Manual S...

Страница 7: ...A 3 3 Installation 1 Connect the power supply cable to the power socket at the rear side Expert Power Control NET 8x 8210 or front side Expert Power Control NET 8x 8211 of Expert Power Control NET 8x...

Страница 8: ...ings to make sure that the same address is used at every reboot 4 2 Network settings with GBL_Conf For changing the network properties manually the program GBL_Conf exe is required This tool is availa...

Страница 9: ...Control NET 8x 8210 8211 Configuration Restart the firmware of Expert Power Control NET 8x 8210 8211 so that the changes will take effect Now click on Search in order to have the new network configura...

Страница 10: ...xpert Power Control NET 8x 8210 8211 into the address line of your internet browser http IP address of Expert Power Control NET 8x 8210 8211 and press LOGIN To enter the configuration menu click on Co...

Страница 11: ...ng menu There are different colors Green text Watchdog is active and receives ping replies Orange text Watchdog is activating at the moment waiting for first ping reply Red text Watchdog is active and...

Страница 12: ...tmask of Expert Power Control NET 8x 8210 8211 All changes need a restart of the firmware to get valid 4 3 2 4 Gateway Here you can change the standard gateway of Expert Power Control NET 8x 8210 8211...

Страница 13: ...istake please activate the bootloader mode of Expert Power Control NET 8x 8210 8211 start Gbl_Conf exe and deactivate IP ACL You can find more information about configuration of IP ACL or have a look...

Страница 14: ...ername of the admin is admin Users are authorized to switch all ports but are not allowed to modify the settings of neither Expert Power Control NET 8x 8210 8211 nor the ports The username of the user...

Страница 15: ...NMP read requests and the private community to SNMP write requests You can see the SNMP communites like read write passwords SNMP v1 and v2 transmit the communities without encryption Therefore it is...

Страница 16: ...nly if your network is fitted for 4 3 6 5 Community private Here you can enter the SNMP private community Use SNMP only if your network is fitted for 4 3 6 6 Download SNMP MIB Here you can download th...

Страница 17: ...me freeware tools available On following events Expert Power Control NET 8x 8210 8211 will send a syslog message Booting up Activation deactivation of syslog Switching of Power Ports You can find more...

Страница 18: ...sh the ok button for two seconds You can check the status of the Power Ports by the color of the Power Port status LED green enabled red disabled 5 2 Switching by Webinterface Go to the website of Exp...

Страница 19: ...under Programs Accessories Communication Connect your PC with Expert Power Control NET 8x 8210 8211 with the PS2 RS232 adaptor cable and plug the device into a outlet Now you can turn on Expert Power...

Страница 20: ...switching window and can be requested via SNMP The temperature sensor can be ordered as additional supplies More information can be found at www gude info or requested at mail gude info Temperature se...

Страница 21: ...n the left side of the program window all Gude devices that are in the network are listed Select the device that should be updated click on Program DeviceFirmware Update and determine the location of...

Страница 22: ...rmation current drivers and software can be found on http www gude info In case of further questions about installation or operation of Expert Power Control NET 8x 8210 8211 please have look at www gu...

Страница 23: ...23 Expert Power Control NET 8x 8210 8211 Declarations of conformity 8 Declarations of conformity...

Страница 24: ...24 Expert Power Control NET 8x 8210 8211 Declarations of conformity...

Страница 25: ...25 Expert Power Control NET 8x 8210 8211 Declarations of conformity...

Страница 26: ...Expert Power Control NET 8x 8210 8211 2010 Gude Analog und Digitalsysteme GmbH 23 08 2010...

Отзывы: