Gude 86009 GHD 100 Скачать руководство пользователя страница 13

Filter Cleaning/Checks – Vario Nozzle Cleaning 

 
Unscrew the adapter on the water supply connection and 
pull out the filter sieve by narrow, flat pliers. Rinse the filter 
sieve with water and insert it back in. A damaged sieve 
needs to be replaced. 
 
ATTENTION! Under no circumstances put the high-
pressure cleaner into operation if the filter sieve is 
damaged or missing. 
 
Use a thin wire to clean the Vario nozzle or to remove 
potential obstructions. See below. 
 

 

Defect Detection 

 
The following table shows possible defects, their potential 
causes and means of their remedies. If you are unable to 
solve the problem nonetheless, approach a qualified 
specialist. 
 

 Prior to maintenance and cleaning, turn the device 

off and unplug it. 
 

 Danger of electric shock. 

 

Symptom Possible 

cause 

Remedy 

The device is not 
plugged into the 
grid 

Plug the device 
into the grid 

The socket is 
defective 

Use another 
socket 

The fuse has 
blown 

Replace the fuse 

The engine 
doesn’t start 

The extension 
cord is damaged 

Try to use the 
device without the 
extension cord 

The fuse has 
blown 

Replace the fuse 

The engine 
stops 

The network 
voltage is not right 

Check the network 
voltage, it has to 
correspond to the 
type label 
specifications 

The fuse has 
blown 

Too weak a fuse 

Connect to an 
electric circuit 
which is properly 
protected with 
respect to the 
high-pressure 
cleaner 
performance 

Excessive 
effective 
pressure 

The nozzle is 
partly clogged 

Clean the nozzle 

There’s air in the 
water hose or in 
the pump 

Turn the high-
pressure cleaner 
off and let it run 
with an open spray 
gun and open 
water faucet long 
enough to reach 
an even effective 
pressure 

Pulsing 
pressure 

The water supply 
is incorrect 

Check whether the 
water supply 
connection 
corresponds to the 

technical 
specifications. The 
smallest water 
hose allowed has 
the diameter of ½“ 
or 
Ø 13mm 

Clogged water 
filter 

Clean the water 
filter 

The water hose is 
clamped or 
broken 

Straighten the 
water hose 

Worn-out nozzle 

Replace the 
nozzle 

The pressure 
is stable yet 
too low 

Worn-out 
Start/Stop valve 

Pull the trigger 5 
times in a quick 
succession 

The water supply 
is not connected 

Connect to the 
water supply 

The engine is 
running, yet 
there is no 
effective 
pressure 

The filter is 
clogged 

Clean the filter 

The high-
pressure 
cleaner turns 
on 
spontaneously 

The pump or the 
spray gun leaks 

Turn to an 
authorized 
specialist 

The device is 
not pressure-
tight 

The pump is not 
pressure-tight 

6 drops per minute 
are acceptable. In 
cases of abnormal 
leakage, it is 
necessary to 
consult the 
problem with a 
specialist 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

21

Содержание 86009 GHD 100

Страница 1: ...86009 GHD 100 86011 GHD 140 86013 GHD 180 English GB Translation of original operating instructions HIGH PRESSURE CLEANER G de GmbH Co KG Birkichstrasse 6 D 74549 Wolpertshausen Deutschland...

Страница 2: ...A...

Страница 3: ...B...

Страница 4: ...C...

Страница 5: ...D...

Страница 6: ...E 4 5 7 1 2 3 8 9 6 10 11 12 13 14 15 16 17 18...

Страница 7: ...ose holder 6 Spray gun 7 Transport wheel 8 High pressure hose connector 9 Safety lock for transportation 10 Spray lancet 11 High pressure hose High Pressure Cleaner GHD 180 86013 picture E 1 On off bu...

Страница 8: ...h respect to damage prior to each use A damaged high pressure hose has to be replaced immediately It is forbidden to use the device in areas threatened by possible explosions When using the device in...

Страница 9: ...essories Use the device in free places with a level and solid ground or floor surface In advance of putting into operation check all the screws and nuts and other fastening components with regard to t...

Страница 10: ...damaged incised or tangled Observe the system voltage the power supply voltage must correspond to the specifications on the type label of the device The extension cord with a small conductor cross sec...

Страница 11: ...tergents which are suitable for high pressure cleaners Turn the high pressure cleaner off Pour the detergent into the detergent container and attach it to the spray gun according to pictures B13 B14 H...

Страница 12: ...re chosen essentially based on their environmental friendliness and disposal methods and can be therefore recycled Returning the packaging into material circulation saves raw materials and reduces the...

Страница 13: ...ond to the type label specifications The fuse has blown Too weak a fuse Connect to an electric circuit which is properly protected with respect to the high pressure cleaner performance Excessive effec...

Страница 14: ...2 79 2009 EN 62233 2008 EN 55014 1 2006 A1 EN 55014 2 1997 A1 A2 EN 61000 3 2 2006 A1 A2 EN 61000 3 3 2008 86009 86011 EN 61000 3 11 2000 86013 Date manufacturer s signature 11 06 2012 Signatory data...

Отзывы: