22
• Please note that our appliances are not designed for
commercial, craft or industrial use. We do not accept
any warranty if the appliance is used in commercial,
craft or industrial operations or in equivalent activities.
• This appliance may only be used as intended. The
manufacturer cannot be held responsible for any
damage caused by non-compliance with the provisions
of the generally applicable regulations and the
provisions of this manual.
Requirements for the operator
The operator must have read the operating instructions
carefully before using the appliance.
Qualification
Apart from detailed instruction by a competent person,
no special qualification is necessary for the use of the
device.
Minimum age
The appliance may only be operated by persons who
have reached the age of 16. An exception is the use
as a juvenile if the use is in the course of vocational
training to achieve the skill under the supervision of an
instructor.
Training
The use of the device only requires appropriate
instruction. Special training is not necessary.
Labelling
To reduce the risk of injury, read the
operating instructions.
Warning / Attention!
Warning of hot surfaces!
Risk of burns!
Distance from persons
Make sure that there are no persons in the
danger zone.
Protect from moisture. Do not expose the
machine to rain.
Attention! There is a risk of fire if the
appliance is covered!
Do not use the appliance indoors.
Fire prohibited
Piezo ignition
European conformity mark
Assembly / initial commissioning
Before assembly, ensure that all transport and
packaging material has been removed from the unit.
Check the heater for damage. If there is any suspicion
of damage, do not install and use the appliance, but
contact the responsible customer service!
This appliance is equipped with a 50 cm gas hose on
the connection side - a 50 mbar cylinder pressure
regulator is absolutely necessary for the function.
Depending on the intended use, we recommend the
following pressure regulators:
• For leisure, such as terrace, outdoors, awnings, party
tents etc. with sufficient ventilation, pressure regulator
50mbar (pre-mounted).
• For household (all indoor systems) according
to TRF1996-5.2.7.2 (supplement with effect from
01.07.2000) and for all commercially used liquid gas
systems (indoor and outdoor) according to UW BGV
D34 §11 Para. 3 and 4: Two-stage safety pressure
regulator ,,t“ 50mbar with manometer (not included in
delivery).
Assembly:
1.
Loosen the 4 screws and washers from the 2 cross
struts (p.6 fig.1)
2.
Fold the floor panel down (p.6 fig. 2+3)
3.
Then screw the base plate to the cross struts from
above (p.7. fig.5). To do this, tilt the heater slightly
backwards (p.6 fig.4) or, if necessary, place the unit
sideways on a soft surface for this step. Use the
previously loosened screws and washers for this.
4.
Connect the gas bottle as described in the
following chapter, open the valve on the gas bottle
(see also p.8+9, fig. 1-5) and check for leaks.
EN
ENGLISH
Содержание 85079
Страница 6: ...5 1 3 2 4 4x ca 20 ...
Страница 7: ...6 6 5 4x 1m 1m 2m ...
Страница 8: ...7 1 2 4 3 5 1 2 ...
Страница 9: ...8 7 5 Gas ON ...
Страница 11: ...10 STOPP 2 1 Gas OFF ...
Страница 12: ...11 2 Gas OFF 2 1 ...
Страница 55: ...54 ...
Страница 56: ...55 ...
Страница 57: ...56 ...