Expert Power Sequencer 8112
© 2021 GUDE Systems GmbH
Operating
onment with many high-energy overvoltage pulses, aging of the overvoltage protection
element can cause a permanent failure of the function.
The surge protection function can only be restored by the manufacturer of the
device. Normally, the device will continue to operate even after the failure of the protect-
ive function.
2.2
Configuration
The EPS 8112 is configured in the delivery state in such a way that the ports are
switched on one after the other every 3 seconds. The switch-off process takes place at
the same interval, but in reverse order. The preset values are chosen in such a way that
normally no adjustments are required. If one uses the EPS 8112 e.g. in a media control
with amplifier, one can arrange the devices in such a way that the amplifier is switched
on last, but switched off first. However, one has the possibility to change the waiting
times and the order of switching off.
Initiate programming mode
a) You enter the programming mode when you switch on and off 2 times. Each switch-
ing operation must be < 2 sec. After that the LED flashes alternately red-green.
b) Please make sure that the ports of the EPS 8112 are switched off so that the pro-
gramming mode can be started.
c) The programming mode is exited directly when the external connector is plugged in.
d) During programming mode, the optional LED for overvoltage protection is not active.
Resetting all values (3 sec switch-on delay and descending switch-
off sequence.)
a) Start programming mode.
b) Switch to "On" within 3 sec.
c) After 5 sec. the red-green change flashes faster.
d) Wait another 5 sec, the LED flashes 3x red.
e) Turn off, and the EPS 8112 is in the switched off state (outside programming mode).
Reversing the direction of the switch-off process
a) Start programming mode.
b) Switch to "On" within 3 sec.
c) After 5 sec. the red-green change flashes faster.
d) Switch off within 5 sec, the LED flashes green 3 times.
e) The EPS 8112 is in the switched off state (outside programming mode).
Set all ports to the same waiting time
a) Start programming mode.
b) Wait 3 sec, the LED flashes 3x orange.
c) If you stay off for 5 sec, you are out of programming mode.
d) Switch to "On" to set the time, the LED flashes red every second.