18
ENGLISH
GB
Inspection and maintenance plan
Time interval
Description
Any other details
As needed
Clean the check valve and the prefilter.
Check the check valve function.
Failures – causes - removal
Failures
Causes
Removal
Engine does not start
No power supply.
Blocked pump wheel
Turn the engine shaft with screwdri-
ver through the fan cover (to release
friction circles sealing that may be stuck
together).
Pump does not suck
Missing, loose or blocked check valve
Check valve is not in water.
Pump without water
Too high suction head.
Air bubbles in the suction pipeline.
Connections not sealed, pump sucks air,
pump is not deaerated.
Fix or clean the check valve.
Immerse the check valve into water.
Fill the pump shell with water.
Check the suction head.
Check the tighten of suction pipeline.
Carefully repeat connection according to
the chapter „Connection“!
Insufficient amount of
water pumped
Too high suction head.
Water level quickly drops down
Check the suction head.
Clean the strainer., Position the check valve
lower.
Clean the pump and replace worn parts.
(qualified workshop)
Reduced switching
intervals
Air pressure in the receiver too low
Control air pressure.
9
Содержание 94173
Страница 61: ...57 BG HWW 2100 G 94173 230 V 50 Hz P1 2100 W 6000 l h 53 m 8 m 35 C 1 1 IG IP44 39 kg 85 dB 100 l 35 C IPX4...
Страница 62: ...58 BG RCD 30mA 35 C 0 C 40 C 16...
Страница 63: ...59 BG DIN 13164 1 2 3 4 12 24 www guede com 49 0 79 04 700 360 49 0 79 04 700 51999 E Mail support ts guede com...
Страница 64: ...60 BG...
Страница 65: ...61 BG 9...
Страница 80: ...76...
Страница 81: ...77...