background image

 

 

3/4” Fall Protection G-Lok’s are to be used in concrete or steel, DO NOT use in wood or any other substrate.   

This product is used in precast concrete only with a compressive strength of at least 5,000 PSI  

 

 

 

3/4” G-Lok 

 

Tested  - 

 

ANSI Z359.1 

Strength  - 

            5,000 lbs / 22kn 

Model  - 

 

RTL #??? 

Color Coded in Bright Yellow Tubing 

Operations and Instruction Manual 

G-Lok Anchorage - Model #????? 

Portable Concrete and Steel Anchorage Connector 

ANSI Z359.1  5,000 lbs / 22kn 

 

 

TM 

Made in the USA 

 

Works in 6” Hollowcore or bigger 

 

Works from 1-1/2” to 4” thick precast  

      concrete 

 

Works from 1/4” to 4” thick steel flange 

 

 

G-Lok’s can be placed in: 

* Horizontal surfaces 
* Vertical surfaces 
* Overhead / ceiling surfaces 

 

Spring 

Main Cable 

Toggle Bar 

Swage 

Hole Plug 

Anchor Loop 

Activator Cable 

G-Lok Part Description 

 

Main Cable   

7x19 Aircraft Cable 

 

Ball Shank   

Stainless Steel 

 

Toggle Bar   

Stainless Steel 

 

Hole Plug   

6061 T6 aluminum 

 

Spring 

 

Zinc Coated Stainless Steel 

 

Swage 

 

Zinc Coated Copper 

 

Return Wire 

1x19 Aircraft Cable 

 

Anchor Loop 

Polyurethane 

 

Company Logo 

Hole Diameter/Size 

Manufactured Date 

Batch Number 
Model Number 

ANSI Z359.1 Mark 

Warning Instructions 

Compliance: 

ANSI Z359.1  5,000 lbs. 

Model #  / Batch 000 

Manufactured 00/00/00 

 

US Patent Pending 

1” 

Warning: 

All persons using this 
equipment must read, 

understand and follow all 
instructions. Failure to do 

so may result in serious 

injury or death. 

1”” 

Hole Diameter/Size 

Patent Markings 

Made in the USA 

Do Not use in wet or 

uncured concrete. Use in 

precast concrete only 

with a compressive 

strength of at least 5,000 

PSI. Use for fall 

Ball Shank 

Cap 

Use For Fall Protection Only !! 

Содержание G-Lok

Страница 1: ...le Bar Swage Hole Plug Anchor Loop Activator Cable G Lok Part Description Main Cable 7x19 Aircraft Cable Ball Shank Stainless Steel Toggle Bar Stainless Steel Hole Plug 6061 T6 aluminum Spring Zinc Coated Stainless Steel Swage Zinc Coated Copper Return Wire 1x19 Aircraft Cable Anchor Loop Polyurethane Company Logo Hole Diameter Size Manufactured Date Batch Number Model Number ANSI Z359 1 Mark Warn...

Страница 2: ...le while pressing on the Cap As the unit passes through the hole the Toggle Bar will flip to the open position Dia B Shows the Toggle Bar open position Activating the Toggle Bar Dia A Dia B Thumb on Activator Cap while inserting Thumb pushing on Activator Cap forcing the Toggle Bar into open position Open position Insertion position 2 ...

Страница 3: ...ve unit from service if a fall has occurred Patch all holes with concrete when job is complete For use by Single User only Pregnant women and minors must not use this product Designed safe working load is 400 LBS 149 3 kg Do not exceed this weight Important Warnings This product is to be used by qualified fall protection personnel only It is to be anchored in accordance with manufacturer s require...

Страница 4: ...ill bits DO NOT USE masonry drill bits Drill a 3 4 diameter hole Drill hole in the center of core hollow Never drill hole closer than 6 to any edge or corner Always inspect a previously drilled hole for deformation Drill another proper hole if needed Inspect the unit for damage each time you use it If damage has occurred dispose of unit Make sure the Toggle Bar is activated in the open position Th...

Страница 5: ...nd ready to pull out The Toggle Bar must be in this parallel position when inserting and removing the unit Only when the unit is activated in the open position is it safe for load bearing Unit in insertion position Push the unit downwards until the Spring fully compresses pushing on Activator Cap will force the Toggle Bar into open Position Placement in Concrete Unit inserted Removal 5 ...

Страница 6: ... hole at least 1 1 2 from any edge or corner Drill a 3 4 diameter hole Drill hole in the center of core hollow Drill center of hole at least 1 1 2 from any edge or corner Always inspect a previously drilled hole make sure the hole is round and a true 3 4 diameter hole Inspect the unit for damage each time you use it If damage has occurred dispose of unit Make sure the Toggle Bar is activated in th...

Страница 7: ...s The center of the hole must be drilled at least 1 1 2 from any edge 7 Push the unit downward until the Spring fully compresses Pushing on Activator Cap will force the Toggle Bar into open position Only when the unit is activated in the open position is it safe for load bearing ...

Страница 8: ...Address Here 8 ...