Product Specific Applications
Personal Fall Arrest:
Diablo 2.0 Tie-Back SRL may be used to support a MAXIMUM 1 PFAS for use
in Fall Arrest applications. Structure must withstand loads applied in the directions permitted by
the system of at least 5,000 lbs. Maximum permitted free fall is 2’ (SRL may be positioned no
more than 2’ below harness dorsal D-ring or 2’ above anchor point). Applicable D-ring: Dorsal.
Restraint:
Diablo 2.0 Tie-Back SRL may be used in Restraint applications. Restraint systems prevent
workers from reaching the leading edge of a fall hazard. Always account for fully deployed length
of lanyard/SRL. Structure must withstand loads applied in the directions permitted by the system
of at least 1,000 lbs. No free fall is permitted. Restraint systems may only be used on surfaces
with slopes up to 4/12 (vertical/horizontal). Applicable D-rings: Dorsal, Chest, Side, Shoulder.
!
WARNING
Use of equipment in unintended applications may result in serious
injury or death. Maximum 1 attachment per connection point.
For all applications: worker weight capacity range
(including all clothing, tools, and equipment) is 130-420 lbs.
Limitations
Fall Clearance:
There must be
sufficient clearance below the
anchorage connector to arrest
a fall before the user strikes the
ground or an obstruction. When
calculating fall clearance,
account for a MINIMUM 2’
safety factor, deceleration
distance, user height, length
of lanyard/SRL, harness stretch,
and all other applicable factors.
Diagram shown is an example
fall clearance calculation ONLY.
Swing Falls:
Prior to installation
or use, make considerations for
eliminating or minimizing all
swing fall hazards. Swing falls
occur when the anchor is not
directly above the location
where a fall occurs. Always
work as close to in line with
the anchor point as possible.
Swing falls significantly
increase the likelihood of
serious injury or death in the
event of a fall.
Diablo
Class A SRL
Fall clearance calculation shown based on standing worker falling
directly in-line with anchor point. Always consider potential swing fall
and other hazards when calculating fall clearance.
*Eliminate Swing Fall whenever
possible! If Swing Fall exists,
always account for additional
fall clearance.