Inspection Log

Notes

If equipment fails inspection IMMEDIATELY REMOVE FROM SERVICE.

User must inspect prior to EACH use. Competent Person other than user must complete
formal inspection at least every 6 months. Competent Person to inspect and initial.

Date of First Use: __________________. Product lifetime is indefinite, as long as it passes
pre-use and Competent Person inspections.

This inspection log must be specific to one Armadillo. Separate inspection logs must be
used for each Armadillo. All inspection records must be made visible and available to all
users at all times.

   

G

ua

rd

ia

Fa

ll 

Pr

ot

ec

tio

  6

30

S.

 2

31

st

 S

t.

, K

en

t,

 W

A

 9

80

32

   

   

 p

ho

ne

: (

80

0)

 4

66

-6

38

 f

ax

: (

80

0)

 6

70

-7

89

   

  w

w

w

.g

ua

rd

ia

nf

al

l.c

om

13

85127 (Rev. B)

Содержание 00245

Страница 1: ...Product Name Armadillo Instruction Manual Part 00245 Do not throw away these instructions Read and understand these instructions before using equipment...

Страница 2: ......

Страница 3: ...n Fall Protection Armadillo This manual must be read and understood in its entirety and used as part of an employee training program as required by OSHA or any applicable state agency This and any oth...

Страница 4: ...sive experience or sufficient professional standing who is considered proficient in planning and reviewing the conformity of fall protection and rescue systems Competent Person A highly trained and ex...

Страница 5: ...he maximum allowable free fall distance for lanyards must not exceed 6 No free fall allowed for non LE SRLs Class A SRLs must arrest falls within 24 Class B SRLs must arrest falls within 54 Forces app...

Страница 6: ...ence of cracks sharp edges deformation corrosion excessive heating alteration excessive wear fraying knotting abrasion and absence of parts Equipment that fails inspection in any way must immediately...

Страница 7: ...iencies including but not limited to corrosion deformation pits burrs rough surfaces sharp edges cracking rust paint buildup excessive heating alteration missing or illegible labels IMMEDIATELY remove...

Страница 8: ...L Structure must withstand loads applied in the directions permitted by the system of at least 1 000 lbs No free fall is permitted Restraint systems may only be used on surfaces with slopes up to 4 12...

Страница 9: ...r deceleration distance user height length of lanyard SRL and all other applicable factors Diagram shown is an EXAMPLE fall clearance calculation ONLY Swing Falls Prior to installation or use make con...

Страница 10: ...tand minimum loads of 3 600 lbs See the following for examples of compatible incompatible connections Connector closed and locked to D ring OK Two or more snap hooks or carabiners connected to each ot...

Страница 11: ...6 10 15 20 25 30 35 40 45 50 55 60 8 9 9 11 7 13 3 14 6 16 17 2 18 3 19 4 19 10 21 4 22 3 53 45 38 33 30 28 26 24 23 21 21 21 For example if the anchorage connector is 6 from the leading edge Y the wo...

Страница 12: ...all Protection 6305 S 231st St Kent WA 98032 phone 800 466 6385 fax 800 670 7892 www guardianfall com 10 Materials aluminum stainless steel zinc plated steel and rubber Casters 4 Locking Bar Large Sma...

Страница 13: ...imes Installation 1 Remove Locking Bar and Hitch Pin assemblies 2 Insert SRL into Armadillo Body SRL attachment point must face in same direction as Triple Locking Carabiner 3 Insert Large Locking Bar...

Страница 14: ...and understand all manufacturer s instructions provided with equipment at time of shipment from manufacturer Compliant with all OSHA 1910 OSHA 1926 Subpart M ANSI Z359 1 2007 and ANSI A10 32 2012 regu...

Страница 15: ...te of First Use __________________ Product lifetime is indefinite as long as it passes pre use and Competent Person inspections This inspection log must be specific to one Armadillo Separate inspectio...

Страница 16: ......

Отзывы: