QX User Manual – Issue B
- 17
-
Engineer
Code-05
The Eng option will only be available if the system is configured for user authorised engineer access.
This option applies to both local and remote engineer access. When the Eng option is selected the
system will prompt for the engineer PIN code to be entered.
05=Engineer
Engineer
Guardall
12:00 Mon 27 Sep
Guardall
0
5
When an engineer logs on to a keypad, all other
keypads in the system will be inoperable and the
display will show
Out of Service
.
✕
or time out (2 minutes)
Once logged on the engineer working time is limited to 8 hours.
Code
Code-06
All users on the system are identified by a code. A user code can be a PIN code (4-6 digits), an
electronic key or proximity card or fob. To change user code, log on to the keypad using your current
code and choose the code option. Then follow the display prompts. All user code changes are
recorded in the system event log. If the code option is not available this means that the system has
been programmed to prevent you from changing your user code, and a new code must be allocated
by the security system manager. If a suitable keypad is used then the user code may be changed to
either an electronic key or proximity card or fob. If you are changing code to an electronic key then
insert the key when the system prompts for a code. If you are changing code to proximity card or fob
then present the card or fob when the system prompts for a code. When using a proximity card or fob
you will not be prompted to re-enter the code. In the example shown the user changes code to 1234.
06=Code
New Code
Not Available
New Code
Enter-
Re-enter Code
Enter-
New Code
Does not Match
2
✓
1
3
4
0
6
Code not unique
Code not the same
Proximity token
presented
Code OK
If another user on the system already uses the chosen PIN code then that user will be alerted when
next logging on to the system. The user whose PIN is known must change PIN code to avoid seeing
the warning message on every log on.